User's Manual

Installing the 100G ERT Module
8. Make sure the index wriggler is parallel to the surface of the index.
Indexes that do not have mounting legs must be attached to the ERT module’s index
backplate mounting posts.
Indexes that have mounting legs only, must be attached to the ERT modules’ index
bracket mounting posts.
Leg bracket
mounting posts
Backplate
mounting posts
Indexes that have mounting legs as well as holes for mounting without legs can be
mounted by using SCR-0015-001 to attach the mounting legs or by removing the two
mounting legs and using SCR-0037-001 to attach the index to the ERT modules’
index backplate mounting posts.
To attach the index to the 100G ERT Module using the mounting legs
1. Get two new screws (part number SCR-0015-001) for attaching indexes to ERT
modules by their legs.
Natural Gas Solutions 100G Installation Guide 77