User's Manual
Table Of Contents
Installing the 100G ERT Module
• For initial programming, hold the FC200SR approximately 1 foot away from
the 100G.
• For reprogramming (30 days or more past initial programming), hold the
FC200SR approximately 4 to 5 feet away from the 100G.
Be sure to program the 100G to the correct mode for the reading technology what will
be used (for example, Fixed Network Mode, Mobile/Handheld Mode, or Hard to Read
Mobile/Handheld Mode). In Endpoint-Link Pro v5.0, you will have access to the one
mode that was defined by your system administrator.
During programming, the 100G ERT module is programmed to the
nearest 100 cubic
feet
; the last two digits (the tens and units) are programmed as zeros (0). Once
programming is complete, however, the ERT module assembly can be read to the
nearest cubic foot.
2. Slowly turn the ERT module drive wriggler two turns in the direction indicated on the
index drive rate. This lets you verify the ERT module is counting properly after
assembly.
IMPORTANT Do not turn the drive wriggler faster than one turn per second.
3. Read the ERT module assembly using the FC200SR. Consult the
EndPoint-Link ERT
Programming Guide
(TDC-0411) or other applicable instructions for details on how to
read an ERT.
• If this reading is higher than the one you programmed in step 1 above, the ERT
module assembly is counting correctly.
• If the ERT module assembly reading is
not higher than what was programmed
in step 1, replace the ERT module with a new one.
Attach the ERT Module to the Meter
After the endpoint has been programmed and is reading correctly, it must be attached to the
meter. Follow the steps below to do this.
Natural Gas Solutions 100G Installation Guide 23