User's Manual

C HAPTER 2
American Meter Installation
This chapter shows you how to install a 100G ERT Module on an American meter.
Before installing the 100G ERT Module, verify that you have:
A compatible meter shown in the Meter Compatibility List.
A compatible index. Itron 100G ERT Modules can be used with standard dial and
direct read (odometer) indexes.
The list of materials defined under Installation Prerequisites in this chapter.
Installation Prerequisites
The following items are required to install the Itron 100G ERT Module.
Materials Supplied by Itron
The following items are supplied by Itron:
100G ERT Modules
New tamper seals
Materials Supplied By You
You must supply the following items to install, initialize, and check the 100G ERT Module
on the meter.
Small and medium flat-blade or Phillips screwdrivers Used to remove and tighten
index and index-cover screws.
Side-cutting plier/wire snips Used for cutting wire seals, if necessary.
Small putty knife Used to remove all traces of old gaskets from the meter.
Meter seals, wire seals, and seal press Used to secure the meter from tampering, if
necessary.
11/32-inch nut driver or other blunt tool Used to securely seat new tamper plugs
over screw holes.
Replacement screws Used to mount 100G ERT Module assembly to meter and
index to module assembly backplates.
FC200SR with EndPoint-Link or EndPoint-Link Pro software Used to program
and check ERT assembly.
Natural Gas Solutions 100G Installation Guide 13