User's Manual

Chapter 4 Actaris Meter Installation
8. Remove the index mounting screws from the meter. Check the screws for length and
corrosion. If they are 1/4 inches long and not corroded, you can use them to attach the
100G ERT Module to the meter.
If the screws are not the correct length, or are corroded, dispose of them properly.
Replace them with the screws listed in
Replacement Screws on page 42.
9. Remove all traces of the old index gasket from the meter. The new 100G ERT Module
has its own gasket.
10. Dispose of the old gasket properly and do not leave it on the customer premises.
Assemble the ERT Module
When installing a 100G ERT Module, the next major step is to create the endpoint module
assembly by combining the endpoint backplate and cover with the meter index. Follow the
procedure below to do so.
To Separate the Cover from the Backplate
1. Obtain a new 100G ERT Module.
44 Natural Gas Solutions 100G Installation Guide