Instruction Manual

6 www.itmtools.com.au
OPERATING PROCEDURES
1. Oscillating control; The oscillating structure is shown in the drawing. When the oscilate arm
is secured to the centre bolt hole, the fan will not oscillate. When oscilate arm is moved to
the off-centre bolt hole, the fan will oscillate 90 degrees. Always ensure the power is turned
off before making any oscillating adjustments
2. Fan Direction; To change the direction of the fan, turn off the power, loosen the direction
changing bolt, adjust the direction of the fan head and tighten the bolt. It is not necessary to
move the base of the fan.
3. Upward and downward tilt adjustment; Turn off the power, hold the head of the fan, loosen
the connecting bolt and stopping bolt, adjust the fan to satisfactory position and tighten up
the two bolts. 19mm Spanner required ( not supplied )
4. Head Height Adjustment (pedestal type only); Turn off the power. Loosen the locking bolt,
adjust the fan head to ideal position and then tighten up the locking bolt. In order to avoid
the fan head falling down suddenly, the fan head must be held when the locking bolt is being
loosened.
5. Installation of the wall fan base; The angle arm of the fan can be installed facing upwards or
downwards. In both cases, the longer of the two locking bolts must be inserted through the
small hole at the end of the angle arm in order to avoid falling off.
6. Speed Adjustment; The fan incorporates 3 speed settings which are controlled by the switch
on the back of the fan head. “0” represents stop. “1” is the lowest blade speed setting, “3” is
the highest.
Maintenance
1. Grease change; After the fan is operated over 2000 hours (or at least once a year),
the grease in the gearbox and bearing should be changed.
2. Care; If the fan is not used for extended periods, it should be cleaned and put into a
dry place.