Specifications
Voltage Minimum Maximum Shutdown
Mode
+5V +5.7V +6.5V Latch Off
+3.3V +3.9V +4.5V Latch Off
+12V1,2,3,4 +13.3V +14.5V Latch Off
5VSB 5.7V 6.5V Auto recovery
Table 15 –Over Voltage protection
4.3 Short Circuit Protection
The power supply shall shut down in a latch off mode when the output voltage is short circuit.
5. Environmental Requirements
5.1 Temperature
Operating Temperature Range: 0°C ~ 50°C (32°F~ 122°F)
Non-Operating Temperature Range: -40°C ~ 70°C (-40°F~ 158°F)
5.2 Humidity
Operating Humidity Range: 20% ~ 90%RH non-condensing
Non-Operating Humidity Range: 5% ~ 95%RH non-condensing
6. Agency Requirements
6.1 Safety Certification.
Product Safety: UL 60950-1 2000Edition, IEC60950-1, 3
rd
Edition
EU Low Voltage Directive (73/23/EEC) (CB)
TUV, CCC
RFI Emission: FCC Part15 ( Radiated & Conducted Emissions )
CISPR 22,3
rd
Edition / EN55022: 1998 + A1: 2000)
PFC Harmonic:
EN61000-3-2:2000
Flicker:
EN61000-3-3: 1995 + A1: 2002
Immunity against:
-Electrostatic discharge:
-Radiated field strength:
-Fast transients:
-Surge voltage:
EN55024: 1998 + A1: 2001 and A2: 2003
-IEC 61000-4-2
-IEC 61000-4-3
-IEC 61000-4-4
-IEC 61000-4-5
9
-RF Conducted
-Voltage Dips and Interruptions
-IEC 61000-4-6
-IEC 61000-4-11
Table 16 –Safety Certification