manual

5.6 Electromagnetic Compatibility
Electromagn
etic
Interference
FCC CFR Title 47
Part 15
Sub Part B
EN55022/EN55024
Conducted B Class
Radiated A Class
Harmonics IEC61000-3-2 Class D
Flicker IEC61000-3-3
ESD
Susceptibility
EN-61000-4-2
8KV by Air,
4KV by Contact
Performance Criteria B
Radiated
Susceptibility
EN61000-4-3
80MHz~1000MHz
(3V/m(mns) Amplitude 80% AM 1KHz
Criteria A
EFT/Burst EN61000-4-4 5KHz, AC: 1KV, DC: 0,5 KV, Performance Criteria B
Surge
Voltage
EN61000-4-5
Line-to-Line: 1KV
Line-to-Ground: 2KV
Performance Criteria B
Conducted
Susceptibility
EN61000-4-6
0.15MHz~80MHz
3V/m Amplitude 80% AM 1KHz
Performance Criteria A
RF
Conducted
EN61000-4-8 50 Hz/3A(ms)/m Performance Criteria A
Voltage Dips
and
Interruptions
EN61000-4-11
30%(Voltage Dips)
60%(Voltage Dips)
>95%(Voltage Dips)
10 ms
100ms
500ms
Criteria B
Criteria C
Criteria C
Leakage
Current
EN60950-1 3.5mA@240VAC
5.7 Safety Agency Requirements
This power supply is designed to meet the following safety
Table X: Product Safety
Product Safety:
UL,cUL UL60950-1
CB IEC60950-1
TUV EN60950-1
CCC
6. Reliability
6.1 Mean Time Between Failures (MTBF)
The MTBF of the power supply shall be calculated utilizing the Part-Stress Analysis method of MIL217F.
The calculated MTBF of the power supply shall be greater than 100,000 hours under the following
conditions:
Full rated load; 120V AC input; Ground Benign; 25°C