Specifications
Multiple rails for +12V
Output
Voltage
+5V +3.3V +12V1 +12V2 +12V3 +12V4 -12V +5VSB
Max. Load 30A 28A 18A 18A 18A 18A 0.5A 4A
Min. Load 1.0A 0A 0.8A 0.8A 0.8A 0.8A 0A 0.1A
Max. Combined
A26 W081
Total Output
W02 W6 W067
Table 5 – Output Loads
Note 1: Maximum continuous total DC output power should not exceed 780 W.
Note 2: Single / Multiple rail(s) for +12V is adjustable by a switch.
3.2 DC Voltage Regulation, Ripple and Noise
The power supply output voltages must stay within the following voltage limits when operating at
steady state and dynamic loading conditions. All outputs are measured with reference to the return
remote sense (ReturnS) signal. The +5V,+3.3V, +12V, -12V and +5VSB outputs are measure at the
power supply connectors references to ReturnS. The +5V and +3.3V is measured at its remote sense
signal (+5VS, +3.3VS) located at the signal connector.
Output Voltage +5V +3.3V +12V1 +12V2 +12V3 +12V4 -12V +5VSB
Load Reg. +/-3% +/-3% +/-3% +/-3% +/-3% +/-3% +/-5% +/-5%
Line Reg. ±1% ±1% ±1%
±1% ±1% ±1%
±1% ±1%
Ripple & Noise 50mV 50mV 120mV 120mV 120mV 120mV 120mV 50mV
Table 7 – Regulation, ripple and noise
Ripple and Noise shall be measured using the following methods:
a) Measurements made differentially to eliminate common-mode noise
b) Ground lead length of oscilloscope probe shall be 0.25 inch.
c) Measurements made where the cable connectors attach to the load.
d) Outputs bypassed at the point of measurement with a parallel combination of
10uF tantalum capacitor in parallel with a 0.1uF ceramic capacitors.
e) Oscilloscope bandwidth of 0 Hz to 20MHz.
f) Measurements measured at locations where remote sense wires are connected.
g) Regulation tolerance shall include temperature change, warm up drift and dynamic load
5