IS-400RSH1UP IS-400RSH1UP Redundant Power Supply (1U-400W with Active PFC) SPECIFICATION Revision: 1.0 727 , . Phillips Drive, City of Industry, CA 91748, USA www.Xeal.com.tw TEL: 626.303.8885 FAX: 626.301.0588 email: sales@istarusa.
TABLE OF CONTENTS 1. General ................................................................................................................................................................................... 3 2. AC Input Specifications...................................................................................................................................................... 3 2.1 AC INPUT VOLTAGE, FREQUENCY AND CURRENT ( RATING: 100V-240VAC, 47-63HZ, 3-1.5A ) .....................................
1. General This is the specification of Model IS-400RSH1UP; it is intended to describe the functions and performance of the subject power supply. This 400 watts Redundant Power Supply with Active PFC (Power Factor Correction) capability, meets EN61000-3-2 and equips Full Range Input features. 2. AC Input Specifications 2.1 AC Input Voltage, Frequency and Current ( Rating: 100V-240Vac, 47-63Hz, 5-2.5A ) The power supply must operate within all specified limits over the input voltage range in Table 1.
3. DC Output Specification 3.1 Output Current / Loading The following table defines power and current rating. The power supply shall meet both static and dynamic voltage regulation requirements for minimum load condition. Power Module Only: Output Voltage +12V +5VSB Max. Load 32A 2A Min. Load 1A 0.1A Total Output 384W 10W Power Module with PDB(Power Distribution Board), Output Voltage +5V +3.3V +12V -12V +5VSB Max. Load 20A 20A 32A 0.5A 2A Min. Load 0A 0A 1A 0A 0.
a) Measurements made differentially to eliminate common-mode noise b) Ground lead length of oscilloscope probe shall be ≤ 0.25 inch. c) Measurements made where the cable connectors attach to the load. d) Outputs bypassed at the point of measurement with a parallel combination of 10uF tantalum capacitor in parallel with a 0.1uF ceramic capacitors. e) Oscilloscope bandwidth of 0 Hz to 20MHz. f) Measurements measured at locations where remote sense wires are connected.
Table 5 – Turn On/Off Timing Item Description Tsb_on-delay Tac_on-delay Tvout_holdup Tpwok_holdup MIN Delay from AC being applied to +5VSB being within regulation. Delay from AC being applied to all output voltages being within regulation. All main output voltage stay within regulation after loss of AC Delay from loss of AC deassertion of PWOK. Tpson_on_delay Delay from PSON# active to output voltage within regulation limits.
3.4 Remote On/Off Control : PSON# The PSON# signal is required to remotely turn on/off the power supply. PSON# is an active low signal that turns on the +5V, +3.3V, +12V and -12V power rails. When this signal is not pulled low by the system, or left open, the outputs (except the +5VSB and V bias) turn off. This signal is pulled to a standby voltage by a pull-up resistor internal to the power supply. Signal Type Accepts an open collector/drain input from the system. Pull-up to VSB located in power supply.
shut down in a latch off mode while the respective output current exceeds the limit as shown in Table 8. When the latch has been cleared by toggling the PSON# single or cycling the AC input power. The power supply module should not be damaged in this condition. Voltage Minimum Maximum Shutdown Mode +5Vsb 110% 160% Latch Off +12V 110% 160% Latch Off Table 8 –Over Current protection 4.
-RF Conducted -Voltage Dips and Interruptions -IEC 61000-4-6 -IEC 61000-4-11 Table 8 –Safety Certification 6.2 AC Input Leakage Current Input leakage current from line to ground will be less than 3.5mA rms. Measurement will be made at 240 VAC and 60Hz. 7. Redundant Power Supply Function 7.1 Redundancy The redundant power supply is 1+1=N (400W+400W=400W) function power supply, each one module is redundancy when any one module was failed.
shutdown due to over current, or shutdown due to component failure.The LED(s) shall be visible on the power supply’s exterior face. The LED location shall meet ESD requirements. LED shall be securely mounted in such a way that incidental pressure on the LED shall not cause it to become displaced. 8. Connections 8.1 DC Wire Harness and Connector Requirements Optional (from PDB to Devices) P1: ATX Motherboard Power Connector Connector housing: 24- Pin Molex 5557 (No.
3 COM Black 18 AWG 4 +5 VDC Red 18 AWG Small 4-Pin: Floppy Disk Drive Power Connectors Connector housing: 4- Pin AMP: 171822-4 or Equivalent Pin Signal Color Size 1 +5 VDC Red 22 AWG 2 COM Black 22 AWG 3 COM Black 22 AWG 4 +12 V3DC Yellow 22 AWG Serial ATA Power Connector This is a required connector for systems with serial ATA devices.
10. Physical Characteristics Size 10.1. Power Supply Dimension: 106 mm(W) x 41.5 mm(H) x 260 mm(D) Mechanical drawing: Name / Dept. Benennung / Description Verkehrsnummer / Reference No. IS-400RSH1UP Rev. 1.0 1U 400W Redundant Power Supply Dokument Format/Size : Doc. No.