Datasheet
All mechanical dimensions are valid at 25°C ambient temperature, if not differently indicated. All data except the mechanical dimensions only have information purposes and are not to be
understood as assured characteristics. Technical changes without previous announcement as well as mistakes reserve. The information on this data sheet was examined carefully and will be
accepted as correct: No liability in case of mistakes. Load with extreme values during a longer period can affect the reliability.
Released 09/2011 Rights reserved for change in technical data!
HYGROCHIP
2/5
Humidity sensors
LabKit with USB-Interface
WINDOWS-Software RECORDER
With the help of this program, which is covered in
the scope of supply, the measured values (relative
humidity and temperature) can be recorded through
the USB-interface and stored on the PC. The
stored file in CSV format is compatible with any
desired spreadsheet program, with which it is pos-
sible to further process, statistically evaluate or
visualise the measurement data.
In addition, the PC-Software also calculates the
dew point, absolute humidity, enthalpy and vapour
pressure from the measured values. The calculated
parameters can also be stored.
System requirements: WIN 98, WIN 2000, WIN
XP or WIN 7, USB-Interface.
Important hint: First connect the USB-Version to
the PC after already installing the software. This
simplifies driver installation and enables
"Plug&Play" feature. Under windows 7, the required
drivers are automatically installed.
Installation: A detailed installation instruction is
provided on the CD, which automatically gets
started on inserting the CD (prerequisites: Internet-
Explorer 5.0 or higher). Follow these instructions for
installation.
Manual Installation: Insert the enclosed CD into
your drive and select "Run" in the start-menu and
then browse to select the file 'setup.exe' under the
path LW:\software\RECORDER\Deu. Then follow
the instructions of the installation program.
First time operation: Connect the Labkit to the
USB-interface of the PC. After first time run of the
software, go to menu option "settings" and select
device type as "HYTELOG 4800" and also select
the type of interface to be used under "connections"
(Note: Mention the virtual COM-port specified dur-
ing driver installation). The remaining settings (Data
rate, Parity, Start and Stop bit) are automatically
selected and need not be changed. If the connec-
tion is established, the data communication ap-
pears on the terminal window. Then select "Close".
The current settings will be stored.
If you are not able to establish data link between
PC and the measuring probe, then first please
check the USB cable connection to the PC. Further
information on debugging is available under FAQ´s
on the CD.
Data recording: First activate the checkbox of all
the measurement channels that are to be recorded.
In 'Text 1' and 'Text 2', you can enter a description,
which will appear in header of the file. The data is
recorded in the file, which is declared as path under
settings. The recording begins with the 'Start' but-
ton.
EXCEL™: The stored file is compatible with CSV-
Format. In order to display the measured data, you
can use graphic tools, for example, the diagram-
assistant. However, other programs can also be
used to graphically represent or evaluate the
measurement data.