WF150K Whole House Central Water Filter INSTALLATION INSTRUCTIONS & OPERATING MANUAL Ver. 02/2020 Copyright ©2005-2020 ISPRING WATER SYSTEMS, LLC. All rights reserved.
We stand behind our products iSpring has been dedicated to providing high-quality drinking water to families across the United States since 2005. From various residential water filtration systems that purify your water in everyday life, to drinking water faucets that deliver pure, healthy, and tasty water to you and your family. At iSpring, we strive for high standard products and aim to make excellent drinking water accessible for all households.
Prior to Installation Read this instruction manual carefully prior to installation. Keep this manual readily available for future reference. Table of Contents User Information ........................................................................................................... 3 Dimensions .................................................................................................................... 4 Product Operation & Specifications ............................................................
User Information The user must adhere to the installation specifications described in this Product Installation and Operation Manual (hereinafter referred to as the “instruction manual”). iSpring is not responsible for damage, loss, or injury resulting from neglect, improper maintenance, or unauthorized modification of the unit. ● The unit should be placed only on flat surfaces. Do not mount on a wall. ● This product is designed for residential use only.
Dimensions TOP VIEW SIDE VIEW • FRONT VIEW Note:all dimensions are in millimeters unless otherwise specified. www.123filter.com | (678) 261-7611 | support@123filter.
Product Operation & Specifications Though testing was performed under standard laboratory conditions, the actual performance of the system may vary based on local water conditions and quality. SPECIFICATIONS Hydrostatic Test Pressure Working Pressure Limits (minimum/maximum) Water Temperature Limits (minimum/maximum) Required Riser Pipe Diameter Electrical Adapter Pressure Tank Thread Inlet/Outlet Connector Peak Flow Rate Model WF150K 350 psi (24.15 bar) 20 ~ 125 psi (1.38 ~ 8.62 bar) 33.8 ~ 102.
Before You Start Warning This system can only be used with 120V/60Hz unidirectional AC power. Do not place anything over the power cord and set the unit where the power cord will not be stepped on or tripped over. Electric shock hazard: Do not overload sockets or extension cords. If there is smoke, abnormal odor, or abnormal noise in this machine, immediately unplug the power of this system to avoid fire or electric shock. Do not touch the plug with wet hands to prevent electric shock.
Material Details 1. 2. 3. Inspect Shipment: One machine and its accessories are included: ① power adapter (white box, 1 pcs.) (adhered to the base), ② sewage pipe (translucent pipe, 1 pcs.), ③ stainless steel braided hose (NPT6M connector, 2 pcs.), ④ stainless steel clamps (in the PE bag, 1 pcs.), ⑤ hex key (in the PE bag, 1 pcs.). Inlet/Outlet Screw Standards: Inlet/Outlet Screw Adaptor: Connect Screw NPT6M 4. Inlet/Outlet Connections Types: Page 7 www.123filter.
5. Bypass Assembly www.123filter.com | (678) 261-7611 | support@123filter.
Installation Requirements (1) Equipment Installation Conditions The installation location should be well-ventilated and protected against wind and rain. Avoid direct sunlight and radiation from any heat sources. The relative humidity of the installation and use environment should not exceed 75% RH. Equipment and pipes installed outdoors should be insulated and frost-proofed. The inlet water must meet the water quality standard of municipal tap water. The water pressure is to be 20 psi - 125 psi.
If the water inlet pressure is higher than 125 psi, a pressure reducing valve must be installed at the water inlet pipe of the water purifier. If the water inlet pressure is lower than 20 psi, a booster pump must be installed at the water inlet pipe of the water purifier to ensure the working pressure meets technical requirements. In addition, a pressure reducing valve or booster pump should be installed between the water inlet pipe and the water supply pipe of this product.
Installation Instructions (1) General Bypass Installation i. Hold the knob or use a bypass tool to rotate the knobs. ii. Water supply will be bypassed when the knobs are horizontal. iii. The bypass is in service status when knobs are oriented vertically. iv. When the bypass is in service status, users can take raw water and filter water samples for testing at the water taking port on either side of the bypass. v. Mount the meter sensor into the meter sensor mounting hole.
(4) Equipment Installation Step 1. Confirm proper installation conditions, then unpack the equipment and verify that all accessories are present. Prepare the installation tools and confirm that the water inlet and outlet pipes, power supplies, sewage pipes, and floor drains at the installation site meet the appropriate requirements. Step 2. Close the indoor water inlet valve completely, then open any faucets in the room to remove the remaining water in the indoor water pipe. Step 3.
Step 9. Open a cold water tap nearby and let the water run a few minutes till the water runs clean or until the system is free of foreign material caused by plumbing work. Step 10. Then, slowly open the water inlet valve (the valve should be opened at an angle of about 45°), fully open the water outlet valve. and let the water run until the air is purged from the unit. Then close the tap. The air in the tank is then exhausted until it is full. Step 11.
Programming the Central Water Filtration System (1) Button Configuration Key Pad Configuration • MENU This function is used to enter the basic setup information required at the time of installation. • SET/REGEN This function is used to initiate an immediate or delayed manual regeneration. • DOWN/UP These buttons are used to increase or decrease the value of the settings while in programming mode.
(c) "↑" / "↓" When the display is in a menu option, these keys can be used to adjust the value or option. (2) Notes (a) Combination key Press and hold "↑" and "↓" at the same time for 3 seconds in the unlocked state to regeneration cycle setting (backwash, rinse, lock/unlock value). Press and hold "MENU" and "SET/REGEN" at the same time for 3 seconds in the unlocked state to enter the user menu settings, such as language, units, smart clean, etc.
(4) Press and hold "MENU" and "SET/REGEN" at the same time for 3 seconds to enter the following user menu settings: SYSTEM LANGUAGE: Choose the system language. UNITS: Choose the system unit of measurement: metric or gallons. SMART CLEAN: When set to ON, the system will perform a 10 (adjustable) minute backwash and rinse if there is no water flow detected after 7 (adjustable) days. The regeneration will occur at the scheduled REGEN TIME.
Operation of WF150K Central Whole House Filtration System (1) Product Functions and Features The central whole house water filtration system utilizes high-quality KDF85 and coconut shell activated carbon to further purify municipal tap water, effectively reducing odor, residual chlorine, and organic content. The automatic back flush system is designed to flush and wash the filter media and move pollutants to the drain.
(d) Water Purification Process: Tap WaterActivated CarbonAlloy Filter MediaPurified Water (2) Structure Automatic multi-way electronic control valve Made with high strength polyphenylene ether (PPE) with glass fiber, making the product hygienic, reliable and durable Corrosion resistance Structural strength, well-designed Filter High-purity copper-zinc alloy filter Polyethylene (PE) liner fiberglass tank Made of synthetic materials, light yet strong Corrosion resistance One-piece, leak-pro
Main Functions Daily Reserve Backwash Override/Rinse Override Forced Regeneration Smart Cleaning Display Format: Metric format and US format are available to meet the different customers' requirements. Multi-Language Function: English, Spanish, French and other languages are available. Continuous water monitoring/Continuous no water monitoring Auto-locking: All keys will lock after 3 minutes during the standby status. Press and hold the “MENU” key for 3 seconds to unlock.
Care of Your Central Water Filtration System The product can be used frequently after installation and commissioning have been completed. With an uninterrupted power supply, the user does not need to perform other operations on the machine. If the equipment fails or experiences other exceptional circumstances, the inlet and outlet valves can be closed (bypass valve is open), and the municipal water supply can be used directly. After removal, open the water inlet and outlet valves of the device.
Troubleshooting ISSUE Unit fails to initiate a regeneration cycle Low water pressure POSSIBLE CAUSE POSSIBLE SOLUTION No power supply Check electrical service, fuse, etc. Power failure Reset time. Iron or scale builds up in line feeding unit Clean pipes or add WDS series or ED2000 before the system. Iron build up inside the valve or tank Clean control and add resin cleaner to clean bed. Increase regeneration frequency.
Water system pressure is too low or too high Install pressure stabilization equipment. Control valve failure Contact us. Filter material performance reduce The back wash flow rate is too large Verify the water pressure is 20 or too small ~ 125 psi. Regeneration start time is incorrect The control valve is inaccurate due to power failure Adjust the current time of the control valve. The regeneration start time is set incorrectly Adjust regeneration start time.
Warranty Registration To register your product for the warranty, visit our website at 123filter.com and go to the “Warranty” tab. We provide a 30-day money back guarantee, a 1-year manufacturer warranty, and lifetime tech support for all of our products. However, we do not have the order information from websites other than 123Filter.com (Amazon, Home Depot, etc.), so please be sure to fill in that information upon registration of your system.
Atlanta, GA USA iSpringFilter.com For questions, comments, or technical support, please contact us at: support@123Filter.com (678) 261-7611 Monday-Friday 8:30 a.m. - 5:30 p.m.