Use and Care Manual
(5) Press and hold "MENU" and "SET/REGEN" at the same time for 3 seconds to enter the
following user menu settings:
(6) Press and hold "↑" and "↓"at the same time for 3 seconds to enter the following user menu
settings:
SYSTEM LANGUAGE:
Choose the system language.
UNITS:
Choose the system unit of measurement: metric or gallons.
SMART CLEAN:
When set to ON, the system will perform a 10(adjustable)minute
backwash and rinse if there is nowater flow detected after 7
(adjustable)days. Theregeneration will occur at the scheduled
REGEN TIME.
BA. WA. DURATION (BACK WASH DURATION) / AIR-DRAW
DURATION:
Users can adjust these parameters at any time with the help of
an application engineer based on the water environment.
LOCK VALUE:
This setting locks the value set in this previous page, and the
end user will not be able to modify it before
this setting is changed to UNLOCK.