Use and Care Manual
Installation Instructions
(1) General Bypass Installation
i. Hold the knob or use a bypass tool to rotate the knobs. The water supply will be bypassed when the
knobs are horizontal.The bypass is in service when knobs are oriented vertically.When the bypass
is in service, users can take raw water and filter water samples for testing at the water taking port
on either side of the bypass.
ii. Mount the meter sensor into the meter sensor mounting hole. This device handles meter and control
functions after connecting to the appropriate controller.
iii. In case of equipment failure or other exceptional circumstances, the bypass can be adjusted to the
bypass position, allowing users to directly use tap water temporarily. After the failure or problem is
resolved, adjust the bypass to the vertical service position
(2) Precautions Before Commissioning
Verify the water inlet pipe and sewage pipe are connected as required. All piping connections must
comply with relevant national standards.
Fix the sewage hose onto the sewer pipe, but do not insert it directly into the sewer pipe. A gap of
100 mm shall be maintained with the bottom of the sewer pipe.
Check whether the pressure of the water source is within the range of 35 psi - 100 psi.
(3) Notes
i. The water pressure requirement is 35~100 psi. If the pressure is higher or lower than this, it is
recommended to install a pressure stabilizer.
ii. The operating ambient temperature requirement is 33.8°F ~100°F. If the temperature is higher or
lower than this, heat preservation measures should be executed.
iii. Do not remove the clips when the system is in operation; relieve the pressure before removing the
clips.
iv. This product should be installed out of reach of children.