Use and Care Manual

Installation Requirements
(1) Equipment Installation Conditions
The installation location should be well-ventilated and protected against wind and rain. Avoid
direct sunlight and radiation from any heat sources.
This equipment is required to be installed indoors. If it needs to be installed outdoors, heat
preservation measures must be taken for the body and pipes, including frost-proof, sun-proof, and
waterproofing measures and insulation.
This sewage pipe should remain open at all times.
If the equipment is installed indoors, the installation equipment must be equipped with water
leakage protection.
The product’s power supply and plug must be installed in a wall position higher than 500 mm
above the ground and equipped with proper grounding, leakage protection, and waterproof devices.
The installation location should be level, and the ground bearing capacity should be greater than
300 kg/m
2
.
(2) Installation Precautions
This equipment should never be tilted or placed horizontally during transportation, installation, or
use.
Ensure that there is proper space around the device and do not apply any external force to the
device or its connecting pipes.
Do not install this product near corrosive substances or gases, as this may cause the product to
corrode.
Do not place flammable items on or near the product.
All inlet and outlet pipes are recommended to use water pipes and fittings that meet the appropriate
standards of domestic drinking water. The connection of water pipes and circuits should comply with
national or industry standards, and the pipe connections should comply with relevant federal
installation regulations.
Pay attention to the height and placement angle of the pipeline when it is connected. After the
pipeline is appropriately connected, there should be no evidence of stress, so as to avoid damage to
the water pipe or the product due to long-term use.
There must be sufficient space (about 10 cm) between the outlet of the sewage pipe and the sewage
to prevent sewage from flowing back to the product; the underground sewage pipe should be 30 cm
higher than the ground, and the sewage pipe should be fixed on the sewage pipe (do not insert the
sewage pipe directly into the sewage.
If the water inlet pressure is higher than 100 psi, a pressure reducing valve must be installed at the
water inlet pipe of the water purifier. If the water inlet pressure is lower than 35 psi, a booster pump
must be installed at the water inlet pipe of the water purifier to ensure the working pressure meets
technical requirements. In addition, a pressure reducing valve or booster pump should be installed
between the water inlet pipe and the water supply pipe of this product.