We stand behind our products Since 2005, iSpring has been dedicated to providing high-quality drinking water to families across the United States. We provide various residential faucets and water filtration systems that purify your water in everyday life and deliver pure, healthy, and tasty water to you and your family. At iSpring, we strive to develop products to the highest of standards and aim to make excellent drinking water accessible for all households.
Prior to Installation Read this instruction manual carefully prior to installation. Keep this manual readily available for future reference. Table of Contents User Information& Guidelines...................................................................................... 4 Product Operation & Specifications ............................................................................. 5 Before You Start .......................................................................................................
User Information& Guidelines The user must adhere to the installation specifications described in this Product Installation and Operation Manual (hereinafter referred to as the “instruction manual”). iSpring is not responsible for damage, loss, or injury resulting from neglect, improper maintenance, or unauthorized modification of the unit. ● The unit should be placed only on flat surfaces. Do not mount on a wall. ● This product is designed for residential use only.
Product Operation & Specifications Though testing was performed under standard laboratory conditions, the actual performance of the system may vary based on local water conditions and quality. SPECIFICATIONS Hydrostatic Test Pressure Working PressureLimits (minimum/maximum) Water Temperature Limits (minimum/maximum) Water pH Range Electrical Adapter Model WCFM400K 350 psi (24.15 bar) 35~100 psi 39~100 °F (4~38 °C) 6.8~9.
Before You Start Warning This system can only be used with 120V/60Hz unidirectional AC power. Do not place objects on top of the power cord and set the unit in an area where the power cord will not be stepped on or tripped over. Electric shock hazard: Do not overload sockets or extension cords. If there is smoke, abnormal odor, or abnormal noise coming from the machine, immediately unplug the system’s powerto avoid fire or electric shock.
Material Details 1. Inspect Shipment: One machine and its accessories are included: ① power adapter (white box, 1 pcs.) (adhered to the base), ② sewage pipe (translucent pipe, 1 pcs.), ③stainless steel clamps (in the PE bag, 1 pcs.), ④ hex key (in the PE bag, 1 pcs.). 2. Inlet/Outlet Screw Adaptor: Connect Screw NPT1M 3. Inlet/Outlet Connections Types: Page 7 www.123filter.com | (678) 261-7611 | support@123filter.
4. Bypass Assembly www.123filter.com | (678) 261-7611 | support@123filter.
Installation Requirements (1) Equipment Installation Conditions The installation location should be well-ventilated and protected against wind and rain. Avoid direct sunlight and radiation from any heat sources. This equipment is required to be installed indoors. If it needs to be installed outdoors, heat preservation measures must be taken for the body and pipes, including frost-proof, sun-proof, and waterproofing measures and insulation. This sewage pipe should remain open at all times.
Before connecting the water inlet pipe, remove any remaining impurities and dust in the pipe and close the main water supply before connecting it. While connecting pipes, keep the pipes as close to the wall as possible. The routing of the pipes should be straight, and the corners should be clear. The pipes should be fixed on the wall after installation. When connecting screw parts, seal rings are generally installed.
Installation Instructions (1) General Bypass Installation i. Hold the knob or use a bypass tool to rotate the knobs. The water supply will be bypassed when the knobs are horizontal.The bypass is in service when knobs are oriented vertically.When the bypass is in service, users can take raw water and filter water samples for testing at the water taking port on either side of the bypass. ii. Mount the meter sensor into the meter sensor mounting hole.
(4) Equipment Installation Step 1. Confirm proper installation conditions, then unpack the equipment and verify that all accessories are present. Prepare the installation tools and confirm that the water inlet and outlet pipes, power supplies, sewage pipes, and floor drains at the installation site meet the appropriate requirements. Step 2. Close the indoor water inlet valve completely, then open any faucets in the room to remove the remaining water in the indoor water pipe. Step 3.
Step 5. The sewage outlet is inserted into the sewage pipe and the stainless steel clamp is locked and clamped tightly outside to prevent high water pressure during sewage discharge, which will cause the sewage hose to break loose and leak sewage. Step 6. Plug in the power adapter and connect the other end of the socket to supply power. Step 7. Place the bypass in the bypass position. Step 8. Slowly turn on the main water supply. Step 9.
Programming the Central Water Filtration System (1) Button Configuration • MENU This function is used to enter the basic setup information required at the time of installation. • SET/REGEN This function is used to initiate an immediate or delayed manual regeneration. • DOWN/UP These buttons are used to increase or decrease the value of the settings while in programming mode. (2) Function Key Description (a) "MENU" Press and hold the key for 3 seconds to unlock the device while in standby mode.
(c) "↑" / "↓" When the display is in a menu option, these keys can be used to adjust the value or option. (3) Notes (a) Combination key Press and hold"↑" and "↓"at the same time for 3 seconds in the unlocked state to regeneration cycle setting (backwash, rinse, lock/unlock value). Press and hold "MENU" and "SET/REGEN" at the same time for 3 seconds in the unlocked state to enter the user menu settings, such as language, units, smart clean, etc.
(5) Press and hold "MENU" and "SET/REGEN" at the same time for 3 seconds to enter the following user menu settings: SYSTEM LANGUAGE: Choose the system language. UNITS: Choose the system unit of measurement: metric or gallons. SMART CLEAN: When set to ON, the system will perform a 10(adjustable)minute backwash and rinse if there is nowater flow detected after 7 (adjustable)days. Theregeneration will occur at the scheduled REGEN TIME.
Operation of WCFM400K Central Whole House Filtration System (1) Product Functions and Features The Central Whole House Water Filtration System is designed for use whenever iron is problematic in the water supply. When water enters the Central Whole House Water Filtration System, it passes through a pocket of compressed air that incorporates oxygen. The water then passes through a filter bed, creating a reaction that separates the iron particles from the water.
(2) Valve This valve is controlled using a simple, user friendly electronic display on a large LCD screen. The main page displays the current date and time while also showing key valve information such as the current capacity setting, volume remaining (meter mode); regeneration days, regeneration days remaining (timer mode).
Care of Your Central Water Filtration System The product can be used frequently after installation and commissioning have been completed. With an uninterrupted power supply, the user does not need to perform other operations on the machine. If the equipment fails or experiences other exceptional circumstances, the inlet and outlet valves can be closed (bypass valve is open), and the municipal water supply can be used directly. After removal, open the water inlet and outlet valves of the device.
Troubleshooting ISSUE Unit fails to initiate aregeneration cycle Low water pressure Control valve without display Poor water quality POSSIBLE CAUSE POSSIBLE SOLUTION No power supply Check electrical service, fuse, etc. Power failure Reset time. Scale builds up in line feeding unit Clean pipes or add WDS series or ED2000 before the system. Inlet of control plugged due to foreign material Remove the piston and clean the control valve.
Filter material performance reduce The back wash flow rate is too large Verify the water pressure is 35 or too small ~ 100 psi. Regeneration start time is incorrect The control valve is inaccurate due to power failure Adjust the current time of the control valve. The regeneration start time is set incorrectly Adjust regeneration start time. For operating procedures, refer to the current time in the control valve manual.
Warranty Registration To register your product for the warranty, visit our website at 123filter.com and go to the “Warranty” tab. We provide a 30-day money back guarantee, a 1-year manufacturer warranty, and lifetime tech support for all of our products. However, we do not have the order information from websites other than 123Filter.com (Amazon, Home Depot, etc.), so please be sure to fill in that information upon registration of your system.
Atlanta, GA USA iSpringFilter.com For questions, comments, or technical support, please contact us at: support@123Filter.com (678) 261-7611 Monday-Friday 8:30 a.m. - 5:30 p.m.