Instructions / Assembly

JDisassembly Diagram of Ballast XH-3 and XH-6:
If ballast fails please disassemble the circuit board according to the below diagram or
directly change the ballast. Please turn off the power before disassembly. Disassembly
steps: disassemble the front wiring row, use a turnscrew to remove two retaining
screws of the fixed slider. Then take out the fixed slider and pull out the ballast
conforming to its own direction. Finally install the new ballast according to the
disassembly steps.
PS: The first ballast in the UV sterilizer control box is the backup ballast. It can be
used immediately in case the other ballasts fail. Just take down the failed ballast from
the wiring row and plug the backup one.
Ballast Model
Ballast Circuit
Board Model
Ballast Power Overall Dimension(cm)
XH-3 XH-UV-3
55
W75W
1
0×3.23×9.12
XH-6 XH-UV-6
75W145W 13.7×4.43×9.12
7