Instructions / Assembly

FTrouble Shooting
Sympton
Solution
Leakage on the UV sterilizer steel pipe nuts
replace the sleeve silicone ring
Water flow out from the quartz sleeve
Replace the quartz sleeve
Leakage on the inlet/outlet
Wind water stop on the
connector ,then fix back to the inlet
Ballast sends alarm, green light is off, lamp
doesn’t turn on
Lamp reaches its service life, replace
it
Lamp still doesn't turn on after replacing
Check the lamp connector wires
Green light is off without alarm and lamp
doesn’t turn on
Ballast is broken, replace it
Lamp turns on, indicator lights and alarm are
abnormal
Indicator lights are broken, replace
them
Timer failure
Do some adjustments according to
the user manual or replace it
UV radiation intensity monitor failure
Do some adjustments according to
the user manual or replace it
Leakage on UV radiation detection head
Replace silicone ring of detection
head
GUser Manual of Timer:
1. Diagram of panel
2. The instrument has been set an initial status before leaving factory. Don’t set it by
your own if not necessary. Once power is on it will start to work.
3. UV lamp manufacturer suggests lamp should be replaced after being used for about
8000 hours to ensure its designed germicidal effect.
4. Once a UV lamp is replaced, the timer needs to be retiming. Press SET” key for
5-10 seconds. Timer will come to zero automatically and start timing again.
5. If you need to reset the timer. First press the shift key for about 5-10 seconds. The
panel will show “29-1”. Then press the up key to set the number to “22-1”. About
10 seconds later the automatic reset is done. Both of the lines will show “0000”.
Now press the shift key until the above line shows 9999” and below