※※※※※※※※※※※※※※※※※※※※※※※ Ultraviolet Water Sterilizer User Manual ※ ※※※※※※※※※※※※※※※※※※※※※※
Table of Contents A. Overview of Ultraviolet Water Sterilizer 1 B. Structure Diagram of Ultraviolet Water Sterilizer 1 C. Mounting Steps and Matters Need Attention 2 D. Notices for Maintenance 3 E. Cleaning and Assembling Steps 3 F. Trouble Shooting 4 G. User Manual of Timer 4 H. User Manual of UV Radiation Intensity Monitor 5 I. Wiring Comparison Chart of Two Versions Ballasts 6 J. Disassembly Diagram of Ballast XH-3 and XH-6 7 K.
Flow Rate Flow Rate Dimension of (Drinking (Pure Inlet/Outlet Water) Water) (Inch) Overall Dimension (㎜) Lamp Max Service Warning Pressure Life System (kg) (hrs) 0.243GPM 0.327GPM Ø51×200±2 5kg >6000 yes 0.406GPM 0.546GPM Ø51×260±2 5kg >8000 yes 0.7GPM 1GPM Ø51×260±2 5kg >8000 yes 1.5GPM 2GPM Ø64×350±2 5kg >8000 yes 4.8GPM 6GPM 1/2" Ø64×520±2 7kg >8000 yes 6.4GPM 8GPM 1/2"~3/4" Ø64×968±2 7kg >8000 yes 9.6GPM 12GPM 3/4"~1" Ø64×968±2 7kg >8000 yes 19.
K、Technical Specifications of Ultraviolet Sterilizer: Watts Input Voltage V Input Input Frequency Current Hz A KC-UV4W 4W×1 220~240 50/60 KC-UV6W 6W×1 220~240 50/60 KC-UV11W 11W×1 220~240 KC-UV16W 16W×1 220~240 KC-UV25W 25W×1 220~240 KC-UV30W 30W×1 220~240 KC-UV55W 55W×1 KC-UV110W KC-UV165W Chamber Material Dosage uW/cm2 0.02A 304# >30000 0.03A 304# >30000 50/60 0.05A 304# >30000 50/60 0.07A 304# >30000 50/60 0.11A 304# >30000 50/60 0.
A、Overview of Ultraviolet Water Sterilizer: The ultraviolet ray is a kind of invisible light wave to the naked eye. It exists on the outside of the purple ray on the spectra. So it is called ultraviolet ray. The ultraviolet ray is subdivided for wave band A (UVA), wave band B (UVB), wave band C (UVC).The wave length of UVC is between 100nm to 280nm. And the most effective germicidal wave band is 253.7nm. 1. Principles : Put the water in the exposure of UVC spectrum at the wave peak of 254nm for some time.
3. Structure diagram of horizontal UV-C water sterilizer: 4. Front panel diagram of horizontal sterilizer Timer or UV radiation intensity ①: monitor Green working light, ②: Red warning light, Indicator lights listed from right to left as 1,2,3、 、 Power switch ③: 5.
J、Disassembly Diagram of Ballast XH-3 and XH-6: If ballast fails please disassemble the circuit board according to the below diagram or directly change the ballast. Please turn off the power before disassembly. Disassembly steps: disassemble the front wiring row, use a turnscrew to remove two retaining screws of the fixed slider. Then take out the fixed slider and pull out the ballast conforming to its own direction. Finally install the new ballast according to the disassembly steps.
I、Wiring Comparison Chart of Two Versions Ballasts: Circuit Board of No-Shell Ballast XH-UV-3-F 6
6. 7. Please add a no fuse breaker when mounting a big horizontal type. Please fix the sterilizer at a certain position by retaining clip, retaining nuts or other fixing device in order to prevent it from dropping because of the shake caused by water and damaging the internal fragile parts. 8. Connect lamp according to “UV lamp wiring diagram”.
F、Trouble Shooting; Sympton Leakage on the UV sterilizer steel pipe nuts Water flow out from the quartz sleeve Solution replace the sleeve silicone ring Replace the quartz sleeve Wind water stop on the connector ,then fix back to the inlet Lamp reaches its service life, replace it Check the lamp connector wires Leakage on the inlet/outlet Ballast sends alarm, green light is off, lamp doesn’t turn on Lamp still doesn't turn on after replacing Green light is off without alarm and lamp Ballast is broken, re
shows “5959”. Finally use the shift key and up key to set the above line to “8000” and the below line to “0000”. Then release both of the keys, 10 seconds later the timer starts to work again automatically. H、User Manual of UV Radiation Intensity Monitor: 1. Diagram of panel: 2. The instrument has been set an initial status before leaving factory. Don’t set it by your own if not necessary. Once power is on it will start to work like diagram1. At the beginning of working UV intensity is low.