Use and Care Manual

4.
3.
Do not use a tube insert on the incoming water line
connection.Thiswillrestricttheflowand/orpressuretothesystem
andcauseittoruncontinuously,possiblefoulingthemembrane.
DrainTube-Non-AirGapFaucet
Connect the tube to the RO
systemdrainfitting. Thisisthefittingonthelooselinebehindthe RO
membrane housing. Tighten firmly so tube will not pull out of
fitting. There is a small cylindrical
flow restrictor
in this line that
willhelpidentifyit.Cuttubetolengthandconnecttheotherendto
thedrainsaddlethatyouinstalledearlier.
Tightenfirmly.
Step3-Install"DrainSaddle"
A.
RED:Connectthetubingfromthewatersupplyconnectorto
Sediment filtercanister.
B.
BLUE:Connectthetubingfrompostinlinefilter(endwithan
elbow
) (or from UV or DI) to the sink top faucet.
C.
BLACK:ConnectthetubingfromFlowrestrictortothedrain
saddle.
D.
YELLOW:Connectthetubingfrompostinlinefilter(endwith a
Tee
) to the storagetank.
1.
SinkWithDisposal-Selectlocationtoplacedrainsaddle.
Best
choiceistheverticalpipeabovethehorizontalpipefromgarbage
disposal. OR Sink Without Disposal-
Best choice is the vertical pipe as high
above the water level in the trap as
possible. The drain line may also run
directly into a laundry tub or open floor
drain.(Drainlinecanrunuphillandeven
distances of more than 100 feet.) Try to
keep the saddle as far away from the
dish washer and waste disposal drains
as you can. Do not use the body ofthe
saddle as a guide for your drill. The threads of the drain saddle
maybedamaged.Youdonotneedaplasticinsertontheendof the tube
that attaches to the drainsaddle.
Toinstall,drilla1/4"hole(3/8"forair-gapfaucet)throughoneside of
the drain pipe. Remove any "burrs" created from drilling. This
willhelppreventdebrisfrompluggingdrainhole.Alignandcenter
Checkallfittingstobesurethattheyareallsecurelytightened.
Step7-SystemStart-UpProcedures
1.
PluginelectricityoftheUVlamp(forUVsystemonly)orplugin the
electricity for Booster pump (for RO system with electric
booster pumponly).
2.
Turnoffstoragetankvalvesothatnowatermayentertank.Turn
onthecoldwatersupplyvalvetothesink.Checkforleaksaround water
supplyconnector.
3.
OpenR.O.faucetonsink.Openwatersupplyconnectortoturnon
watertotheROsystem.Youwillhearwatergurglingandfillingthe
ROsystem.Watermaytake10-15minutesbeforedrippingout
2.
gasketonholebetweenpipeanddrainsaddle.
thedrainsaddlewiththeholeinthedrainpipe.
drain saddlefirmly.
Align the hole in
Tighten downthe
8
5