remove the nut from the 1/4” knob and slip it onto the tubing. Then push the tubing onto the knob, and tighten the nut
down to create the seal.
2.0 Conditioning the Filter
The filter should now be ready to fill with water. To avoid any problems caused by airlocks in the filter housing, the unit
should be held upside down over the kitchen sink. Partially turn on the cold tap, then pull the valve stem on the diverter
valve to allow the water to gently fill the unit for the first time. Check for leaks. During the first fill, it may take some time
for water to appear through the outlet spout. Once the unit is full, it can be placed upright. Allow the water to run into the
sink for a minimum of 10 minutes, and then stand the filter upright for 24 hours without using it to condition it to the
source water. After 24 hours, flush the filter for another 5 minutes, and then the filter is ready for regular use.