Owner Manual
Table Of Contents
- Prior to Installation
- Installation Steps
- Step 1: Installing the Feed Water Adapter (AFW43)
- Step 2: Installing the RO Faucet
- /How to install an Air-gap Faucet (optional)
- Note: The installation instructions below are for your reference only. An air gap faucet is not included with this system.
- Drill a hole in the kitchen sink or countertop if there isn't already a spare one. Refer to the manual of the faucet when determining the size.
- Place the front plate and the rubber washer on the base of the faucet. Mount the faucet on the countertop.
- From under the sink, connect the RO system pure water output line to the faucet stem. Attach the black drain line from the RO system to the drain input barb. Attach one end of the faucet drain line to the drain output barb and the other end to the dra...
- Step 3: Installing the Drain Saddle
- Step 4: Installing the Vertical Filters: Stages 1, 2, and 3 /
- Step 5: Installing Tank Shut-off Valve (TSV)
- Step 6: Installing the Reverse Osmosis Membrane
- Step 7: Tubing Hook Up (see figure 5 above to see letters not shown below)
- Step 8: System Start-up (model specific sub-steps are marked with a *)
- Section 1: iSpring RO System Maintenance
Installation Tips
How to Use the Quick-connect Fittings
To Connect:
1. See Figure 1. Check and cut the tubing end squarely and cleanly with a utility knife or
scissors.
2. Make a 5/8" mark at the end of the tube so you will be able to confirm when the tube is
inserted fully into the fitting.
3. Remove the blue lock clip from the fitting with your nail. If the lock sleeve pops out of the
fitting when doing this, pop it back in.
4. Insert the tube into the fitting until you reach the 5/8" mark on the tube. You will feel
resistance when the tube reaches the small rubber O-ring inside the fitting. You will need to
wiggle the tube and apply additional pressure to get it past this O ring and create the seal. If
the tube is not 5/8" into the fitting and past the O-ring, no seal will be created, and
leaking will occur.
5. Once the tube is fully inserted, pop the blue lock clip back on the fitting. This will lock the
tube in place and prevent it from moving.
Figure 3
Figure 2
Figure 1
Page 6 www.123filter.com | (678) 261-7611 | Support@123Filter.com