Owner Manual
Table Of Contents
- Prior to Installation
- Installation Steps
- Step 1: Installing the Feed Water Adapter (AFW43)
- Step 2: Installing the RO Faucet
- /How to install an Air-gap Faucet (optional)
- Note: The installation instructions below are for your reference only. An air gap faucet is not included with this system.
- Drill a hole in the kitchen sink or countertop if there isn't already a spare one. Refer to the manual of the faucet when determining the size.
- Place the front plate and the rubber washer on the base of the faucet. Mount the faucet on the countertop.
- From under the sink, connect the RO system pure water output line to the faucet stem. Attach the black drain line from the RO system to the drain input barb. Attach one end of the faucet drain line to the drain output barb and the other end to the dra...
- Step 3: Installing the Drain Saddle
- Step 4: Installing the Vertical Filters: Stages 1, 2, and 3 /
- Step 5: Installing Tank Shut-off Valve (TSV)
- Step 6: Installing the Reverse Osmosis Membrane
- Step 7: Tubing Hook Up (see figure 5 above to see letters not shown below)
- Step 8: System Start-up (model specific sub-steps are marked with a *)
- Section 1: iSpring RO System Maintenance
System Installation
Prior to Installation
*Installation is to comply with all local laws and regulations*
Inspect the package
Open the box and remove all of the components. Inspect them to ensure nothing was damaged
during shipping. If any part is cracked or broken, please immediately contact iSpring Customer
Support for a replacement. Identify and get familiar with the components.
Recommended tools list
● Variable speed drill with two bits: 1/4" (for drilling a hole on PVC drain pipe), 1/4" hollow
diamond (for drilling a hole on the countertop for drinking faucet)
● 5/8", 9/16" open-end wrench, or adjustable wrench, pliers
● Phillips head screwdriver
● Scissors or utility knife
Operating conditions
● Minimum recommended water pressure: 30 psi
● Maximum water pressure: 70 psi; otherwise, a pressure regulator (model: APR70) is
required to lower the psi to the maximum level.
● Operating water temperature range: 40 – 100 °F (4 - 37 °C) (This RO system is NOT
designed for HOT water). The RO process will be faster and more efficient within the
operating range with the water temp on the warmer side and less so on the colder side.
● Maximum TDS: 750 ppm
● Install this RO system in a location where it is safe from hot/cold weather and direct
sunlight. Avoid hitting, dropping, or dragging the system, as this can cause cracks and
leaks.
The Requirements of the Influent Water Characteristics
Total Coliforms
None
Fluoride (mg/L)
1
Heat - resistant coliforms
None
Turbidity (NTU)
1
Escherichia Coli
None
pH
>6.5 and <8.5
Bacterial colony count (CFU/ml)
100
Aluminum (mg/L)
0.2
Arsenic (mg/L)
0.01
Iron (mg/L)
0.3
Cadmium (mg/L)
0.005
Manganese (mg/L)
0.1
Chromium (Hexavalent) (mg/L)
0.05
Copper (mg/L)
1
Lead (mg/L)
0.01
Zinc (mg/L)
1
Mercury (mg/L)
0.001
Chloride (mg/L)
250
Selenium (mg/L)
0.01
Sulfate(mg/L)
250
Cyanide (mg/L)
0.05
TDS (mg/L)
1000
Fluoride (mg/L)
1
Hardness (mg/L)
450