Owner Manual
Table Of Contents
- Prior to Installation
- Installation Steps
- Step 1: Installing the Feed Water Adapter (AFW43)
- Step 2: Installing the RO Faucet
- /How to install an Air-gap Faucet (optional)
- Note: The installation instructions below are for your reference only. An air gap faucet is not included with this system.
- Drill a hole in the kitchen sink or countertop if there isn't already a spare one. Refer to the manual of the faucet when determining the size.
- Place the front plate and the rubber washer on the base of the faucet. Mount the faucet on the countertop.
- From under the sink, connect the RO system pure water output line to the faucet stem. Attach the black drain line from the RO system to the drain input barb. Attach one end of the faucet drain line to the drain output barb and the other end to the dra...
- Step 3: Installing the Drain Saddle
- Step 4: Installing the Vertical Filters: Stages 1, 2, and 3 /
- Step 5: Installing Tank Shut-off Valve (TSV)
- Step 6: Installing the Reverse Osmosis Membrane
- Step 7: Tubing Hook Up (see figure 5 above to see letters not shown below)
- Step 8: System Start-up (model specific sub-steps are marked with a *)
- Section 1: iSpring RO System Maintenance
Note: Stages 6 and/or 7 only exist on specific models.
Stage 1 – 3 Pre-Filters
Replace every 6 months or sooner if you notice a decrease in water flow or quality. The
replacement frequency depends on your water usage and source water quality. Changing the pre-
filters according to the schedule is essential to protect the RO membrane from chlorine and other
damaging contaminants.
How to change the stage 1 – 3 pre-filters:
1. Shut off the cold water supply and tank valve, and open the RO faucet to depressurize the
system. Place a bucket or towel under the system to catch any water spills.
2. If there is enough room under the sink and the filter system is hung on the wall, you can
twist the filter housing off without removing the system from the wall. Otherwise, you will
need to pull the system out, lay it down, and remove the housings at that point. Be careful
with the tubing connections when removing the system.
3. Twist off the filter housings in a counter-clockwise direction using the filter housing
wrench.
4. Refer to Installation Step 1.1 to install the new vertical filter cartridges, and tighten the filter
housings back on. Remember not to over tighten them, or they will be hard to unscrew next
time.
Stage 4 RO Membrane
Replace every 2-3 years or sooner if the TDS level starts increasing. Check the TDS level at least
once a month to monitor the system’s performance. The TDSrejection rate should be 90%+. To
calculate the rejection rate, divide the RO water TDS into your tap water TDS and subtract from 1.
For example, 20 (RO TDS) / 200 (Tap water TDS) = 0.1 1-0.1 = 0.9 so the TDS rejection rate
would be 90%. (NSF/ANSI STANDARD 58 for RO water filter).
Figure 17
Page 16 www.123filter.com | (678) 261-7611 | Support@123Filter.com