Datasheet
PARAMETER MIN TYP MAX UNITS TEST CONDITION
ELECTRICAL CHARACTERISTICS ( T
A
= 25°C Unless otherwise noted )
Input Forward Voltage (V
F
) 1.2 1.5 V I
F
= 10mA
Reverse Current (I
R
) 100 μAV
R
= 6V
Output Peak Off-state Current ( I
DRM
) 100 nA V
DRM
= 400V (note 1 )
Peak Blocking Voltage ( V
DRM
) 400 V I
DRM
= 100nA
On-state Voltage ( V
TM
) 1.5 3.0 V I
TM
= 100mA ( peak )
Critical rate of rise of off-state
Voltage ( dv/dt ) ( note 1 ) 10 V/μs
Critical rate of rise of commutating
Voltage ( dv/dt ) ( note 1 ) 0.1 0.2 V/μs I load = 15mA,
V
IN
= 30V ( fig 1. )
Coupled Input Current to Trigger ( I
FT
)(note 2 )
MOC3020 30 mA V
D
= 3V ( note 2 )
MOC3021 15 mA
MOC3022 10 mA
MOC3023 5 mA
Holding Current , either direction ( I
H
) 100 μA
Input to Output Isolation Voltage V
ISO
5300 V
RMS
See note 3
7500 V
PK
See note 3
Note 1. Test voltage must be applied within dv/dt rating.
Note 2. Guaranteed to trigger at an I
F
value less than or equal to max. I
FT
, recommended I
F
lies
between Rated I
FT
and absolute max. I
FT
.
Note 3. Measured with input leads shorted together and output leads shorted together.
R
IN
1
3
6
5
4
V
CC
+
-
2kΩ
V
IN
~
STATIC
dv/dt
COMMUTATING
dv/dt
2
+5v
V
CC
0v
120Ω
FIGURE 1
R
L
17/7/08
DB91045m-AAS/A5