User Guide
similar, but are not interchangeable.
Outdoor Models:
• Input: 120 VAC 60 Hz, 30 VA (Domestic), 230 VAC, 50 Hz,
30VA (International) 240 VAC, 50 Hz, 30VA (Australia)
Indoor Models:
• Input: 24 VAC, 60 Hz, 30 VA (domestic) or 24 VAC, 50 Hz,
30 VA (International and Australian)
All Models:
• Station Output: 24 VAC at 0.5A, 1.0A (maximum total)
• Master Valve/Pump Start Relay Output: 24 VAC at 0.375A
• 2.0A Slow-blow Fuse
• Battery Back-up (time, day and date)
• Operating temperature range: 32˚F to 140˚F (0˚C to 60˚C)
Caution: The Rain Dial is designed to operate 24 VAC valve
solenoids rated at 0.25A (6 VA). Current total load must not
exceed 1.0A maximum. A maximum of two solenoids per station
terminal may be used, but not to exceed 0.5A per station. No
more than three solenoids (plus MV/Pump circuit) should be on
at any one time .
To prevent controller damage, do not link the valve common wire
of two or more controllers. Use a separate valve common wire for
each controller.