Operation Manual
46 • Technical information
8. TECHNICAL INFORMATION
Important: All information with nominal battery charging!
Operating temperature –10°C to +60°C (14°F to 140°F)
Temperature measurement
Measuring range: –40°C to +90.0°C (–40°F to 194°F)
Resolution: 0.1°C (0.2°F)
Measuring accuracy: +/– 1°C ranging from 0°C to +40°C
+/– 2°C for the rest
Pressure measurement (Barometer/Altimeter)
Measuring range: 300–1100 hPa (mBar) (8.86–32.48 inHg)
(equals approx. –380 m to +9000 m)
Resolution: 0.1 hPa (0.01 inHg)
1 m (3.3 ft)
rel. measuring accuracy: +/– 0.5 hPa at specific pressure
abs. measuring accuracy: +/– 1 hPa over 500–1100 hPa
Measuring frequency of every 30 seconds
the Altimeter: With stopwatch running: Every 2–4 seconds
Compass
Measuring range: 0 to 359°
Resolution: 1°
Measuring accuracy: +/– 3°
Quartz watch mov. variance: +/– 1 second/month
Power supply: 1 CR2032 3.0V battery
Dimensions: 67 g (including battery); visible display Ø 30 mm