Product Manual

Page 19 of 28
generator cycle on or off. The slight variation has no appreciable effect in the operation of motors,
lights, and most appliances.
Connecting Electrical Loads (Portable Power Generation)
You will want to be careful when connecting loads so as not to overload the generator, especially if
you are powering devices with motors that require a higher starting power load.
WARNING
Do not overload generator. Make sure that combined starting and running loads do not exceed rated
capacity of generator. Overloading the generator can cause damage to the generator and attached
electrical devices, and may result in fire.
Using as a Portable Power Source. Connect electrical loads one at a time according to the following
instructions:
1. Allow engine to reach operating speed by allowing it to warm up for approximately 5 minutes
before connecting electrical devices.
2. After engine is warmed up, begin by connecting the items that require the highest wattage first.
The recommended sequence is as follows:
a. Connect items with motors such as refrigerators, freezers, air conditioners, or small hand
tools, one at a time. Let each motor stabilize before connecting the next device.
b. Connect any lights you are planning on powering.
c. Connect voltage sensitive equipment such as electronics via surge protectors. Plug
devices such as televisions, computers, and microwaves into a UL listed voltage surge
protector, then plug the surge protector into the generator.
Using as a Back-up Power Source for a Building. Each transfer switch installation will be unique.
Proper instructions for how to safely bring the generator online with the building's electrical system
should be provided by the installing electrician, who should also provide personal instruction to the
owner/operator.
Failure to follow the proper procedure as provided by the electrician could expose persons to the
hazards noted above.
Stopping
Stop the engine using the following steps:
1. Disconnect all loads to the generator.
2. Turn the engine key switch to the OFF position.
3. Turn the gasoline line shut off valve to the OFF position.
4. Remove the key from the starter to prevent accidental starting of the engine.
Storage & Exercise of Generator
When you are finished using the generator, you must:
1. Disconnect all loads to the generator.