Product Manual

Page 9 of 12
Troubleshooting
Use the table below to troubleshoot problems before contacting service personnel or your local
dealer. If the problem continues after troubleshooting, call your local dealer for assistance.
Failure
Possible Cause
Corrective Action
Air mover is not
running.
No power input.
Plug in the air mover. Check the circuit
breaker.
Switch is not turned on.
Turn the switch to “on”.
Air mover fan has a wheel jammed.
Remove any material jamming the fan
wheel.
Intake or exhaust is blocked.
Turn the unit off and allow it to cool.
Remove the blockage.
Accumulation of dirt on fan blades.
Clean the air mover fan blades.
Parts Diagram
Parts List
Reference
Part Name
1
Grid Cover (Motor Side)
2
Receptacles
3
Over-Current Protector
4
Left Housing
5
Power Cord
6
Switch Knob
7
Switch Panel
8
Capacitor
9
Switch
10
Pressure Block
11
Air Outlet Grid Cover
12
Kick Stand
13
Motor