3. Connect power plug to power source (AC 110V, 60Hz).
4. Turn on the power switch and run the machine for 15 seconds to warm up to the operating temperature.
5. Place package on the table top, directly above the sealing head. Allow the package to contact the two package
stops.
6. Manually pull the strap to encircle the package. Or press manual feeding button to gain enough for encircling
package.
7. Insert strap end into slot, then machine will work automatically. Keep your hands away of the strap and slot
during strapping.
8. After strapping, take the package away.
NOTE: Some adjustments may be required to let the machine work well. Please refer to the below section
ADJUSTMENT INSTRUCTIONS to adjust accordingly.
WARNING: DO NOT sit on this machine as a bench.
CAUTION: Take care of your fingers during operation.
ADJUSTMENT INSTRUCTIONS
1. TEMPERATURE ADJUSTMENT
Open the top cover of the machine and find the temperature adjustment knob. Refer to Fig. 5.
The temperature increases when turning the knob on the transformer clockwise (The larger the number pointed is,
the higher the temperature is). The adhesive affection will not be very good if the temperature too high or too low,
so adjust in small increments. Normally, switch it on 4-6.
NOTE: If the temperature is adjusted too high (above 6), the high temperature heating filament is easy to be burnt
out.
2. WIDTH ADJUSTMENT
This machine is designed specially for use with PP straps with length between 0.24in. (6mm) and 0.6in. (15mm).
Adjust the distance between (2) (3) (4) and benchmark’ width (1) or (2) to fit various width of strap. Generally, it
should be 1mm wider than actual width of PP width. If the PP with poor quality, the distance should be larger.
Otherwise send back will be a failure. Refer to Fig. 6.
3
4
5
2
1
Fig. 6 Width Adjustment
Fig. 5 Temperature adjustment knob