Product Manual

Page 11 of 19
1. Secure the bracket to the wall using the dowels at about 1200mm height appropriate for the tank's
dimensions. Make sure that the wall is solid and thick enough for the dowels. Do not interfere with
hydraulic tubes or electric lines.
2. Secure the pump to the bracket 2.
3. Connect the flexible suction tube 4 to the pump using the clamp provided.
4. Connect the rigid suction 7 to the end of the flexible suction tube 4 using the elastic clamp provided.
5. Put the bung adapter 6 into the drum hole.
6. Put the rigid suction tube 7 into the pump and secure it in place.
Part#
Description
Quantity
Part#
Description
Quantity
1
Oil pump
1
3-4
Extension 200mm tube
1
2
Bung adapter
1
3-5
Foot connection
1
3-1
Top connection
1
4
Foot valve
1
3-2
Extension 500mm
1
5
Filter
1
3-3
Extension sleeve
1
Depending on the length of the suction tube, determine the desired extension length (see the
examples).
Remove filter and foot valve from the stub pump, screw the extension tube on (with top connec-
tion), then screw filter and foot valve on the extension tube (foot connection end).
Note: 1:1 stub pump's adapter is different than with others.