Product Manual

Page 9 of 19
Assembly Instructions
DIRECTLY FIT PUMP INTO DRUM
Insert the suction tube of pump into the drum and secure with ring nut. Suitable for commercial
drums with 57 diameter hole and threading 2'' BSP.
Fit an oil delivery tube for oil outlet of the air operated pump using only high quality tubes
(normally 1/2'' or 3/4'', according to DIN-SAE norms), by means of 1/2'' BSP threading fitting.
Oil delivery pistol: connect delivery tube with delivery pistol using suitable pipe fittings, and point
the pistol in the desired area.
Air inlet connection is 1/4'' quick plug (or 1/4'' NPT female) in all versions.
Compressed air connection (to be supplied by the customer) should be done using suitable
tubes.
A pressure regulator to keep the pump's working pressure at the best possible level (max 5-8
bar) between the pump and the compressed air line.
A cut-off switch can enable the operator to stop the pump at any given moment by cutting the air
supply off between the pump and the compressed air line.
Switch on all switches.