Product Manual
Page 8 of 18
Assembly Instructions
DIRECTLY FITTED PUMPS INTO THE DRUM
• Insert the suction tube of pump into the drum and secure with ring nut, suitable for commercial
drums with 57 diameter hole and threading 2'' BSP.
• Fit an oil delivery tube for oil outlet of the air operated pump using only high quality tubes
(normally 1/2'' or 3/4'', according to DIN-SAE norms), by means of 1/2''BSP threading fitting.
• Oil delivery pistol: Connect delivery tube with delivery pistol using suitable pipe fittings, and point
the pistol at right place.
• Air inlet connection is 1/4'' quick plug (or 1/4'' NPT female) in all versions.
• Compressed air connection (to be supplied by the customer) should be done using suitable
tubes.
• A pressure regulator to keep the pump's working pressure at the best possible level (max 5-8
bar) between the pump and the compressed air line.
• A cut-off switch can enable the operator to stop the pump at any given moment by cutting the air
supply off between the pump and the compressed air line.
• Switch on all switches.