Activating the Digital Display
Press the RESET key pad to clear the meter before starting a new dispense cycle. This is the best
way to activate the meter, because it also clears the quantity of the last dispense cycle. The digital
display can also be activated by pressing the MENU key pad or by running fluid through the meter.
Calibrating Automatically
- Press Reset key for 1 second and Area 1 shows .000 L;
- Keep running fluid through the meter until the fluid running out of the certain measuring cylinder. The
display will show certain value as *.**L, press the Menu key for 3 seconds. The meter will enter
instrument calibration mode and Area 1 shows 00*.**L;
- Press Menu key to move the flashing digital, press Reset key to choose number, enter the fluid
volume and press Menu key again for 3 seconds, then exit the calibration mode. The calibration is
settled.
Showing Current Correction Factors
- Press Menu key and Reset key together. The display will show the correction factor, which can be
reset.
Resetting the Resettlement Total
- Press Menu key for 10 seconds, the accumulated total will be reset to be “0”.
Changing the Measurement Units (L / GAL/ PT / QT meter only)
- Move the flashing display to Area 2 by pressing Menu key, then press Menu key to choose
measurement unit.
-Press Menu key over 3 seconds to exit the setting mode.