Product Manual

Page 13 of 30
New Installation
1. Relieve the pressure.
2. Close the fluid shut-off valve at each dispense position.
3. Make sure the main fluid outlet valve at the pump is closed, the air pressure to the pump motor is
adjusted, and the air valve is open. Slowly open main fluid valve.
4. Place the hose end (with no dispense valve connected) into a container for waste oil. Secure the
hose in the container so it will not come out during flushing. If you have multiple dispense positions,
first flush the dispense position farthest from the pump, and work your way toward the pump.
5. Slowly open the shut-off valve at the dispense position. Flush out a sufficient amount of oil to
ensure that the entire system is clean, and close the valve.
6. Repeat step 5 at all other dispenses positions.
Note: If you want to adjust the angle of the nozzle, you can loosen the #4 swivel nut, then turn the
nozzle to your desired position and tighten the nut.
Existing Installation
1. Relieve the pressure.
2. Loosen and disconnect the hose from the old dispense valve (the one that you are replacing).
3. Thread the extension into the outlet of the dispense valve, and tighten firmly.
4. Apply thread sealant to the male threads of the hose fitting, thread the hose fitting into the swivel,
and tighten firmly.
5. Thread the new nozzle or nozzle adapter onto the extension, and tighten firmly.
6. Open all dispense position shut-off valves, and start the pump to pressurize the system. See the
Operation section for proper operation.
7. For metered dispense valves, to ensure dispensing accuracy, purge all air from the fluid lines and
dispense valves before you use them.
Grounding
Proper grounding is an essential part of maintaining a safe system.
To reduce the risk of static sparking, ground all system components per local and national electrical
codes.
Refer to the user manual for the pump and other system components to ground the following:
- Pump: Follow manufacture’s recommendations.
- Air and Fluid hoses: Use only grounded hoses.
- Air compressor: Follow manufacture’s recommendations.
- Fluid supply container: Follow your local code.
- To maintain grounding continuity when flushing or relieving pressure, always hold a metal part of the
valve firmly to the side of a grounded metal pail, then trigger the valve.