Product Manual

Page 10 of 20
Assembly
Install a 1/4" air nipple (not included)
1. Wrap the 1/4 in. air nipple with pipe thread seal tape (not included), and then thread it into
the air inlet on the air tool.
2. Connect the 3/8 in. I.D. air hose (not included) to a quick-connect coupler (not included) and
then to the air nipple.
3. Turn on the air compressor and set it to 90 PSI. Do not exceed the recommended air
pressure of 90 PSI.
4. Check the air connection for leaks.
Install the socket
To install or remove a socket, slide the socket (1) on or off the square drive (2).
Lubrication
Air tools require lubrication throughout their lifetime. The air motor and bearing use compressed
air to power the tool. Compressed air contains moisture which may rust the air motor and other
internal parts if the tool is not kept lubricated. Failure to lubricate the tool properly will dramatically
shorten the life of the tool and will void the warranty.
The tool must be manually lubricated before its initial use. If you are not using a lubricated air
supply, the tool must be manually lubricated before and after each use, as well as after each hour
of continual use.
To manually lubricate the tool, add a few drops of pneumatic tool oil to the tool's air line
connection.