Attach the manual handle (#24) to the tube container (#19). See Figure 5.
Figure 5
The completed assembly is shown below in Figures 6 and 7.
Figure 6 Figure 7
Before Each Use
WARNING
Disconnect from air supply before changing accessories or servicing.
Before each use, prime the grease gun by following the Operation Instructions until grease flows from
the tip (#10a). If the grease gun does not prime properly, follow the instructions below for venting
trapped air. Inspect the overall condition of the grease gun and look for:
a damaged hose,
loose hardware,
misalignment or binding of moving parts,
cracked or broken parts,
damaged electrical wiring, or
any other condition that may affect its safe operation.
Venting Trapped Air
Remove the gun body from the tube container by turning counter-clockwise.
Install the manual handle to the tube container by turning clockwise. Make sure that the manual
handle is mounted securely onto the tube container.
Pull up and then depress the lever of the manual handle to inject a small amount of grease.
Repeat until enough grease is released.