Brochure

Parts Catalog Ground Mount
Page 21
2016 v1.85
support | ironridge.com | (800) 227-9523
Ground Mount Overview
The IronRidge Ground Mount System scales to support a wide range of site and terrain challenges. This system consists
of components that allow for installer-supplied steel pipe or mechanical tubing to combine with the XR1000 rail
assembly for simple, rapid, cost eective ground mounting.
Download AutoCAD File
Download PDF Preview
2" CROSS PIPE LENGTH
CANTILEVER,
40% OF MAX E-W
PIER SPACING
E-W PIER SPACING
CANTILEVER,
40% OF MAX E-W
PIER SPACING
E-W PIER SPACING
7'-6"
TOP CAP
RAIL CONNECTOR
B
EQ.
EQ.
11'-0" MAX.
7'-6"
2'-6" MAX.
EXPOSED
ABOVE GRADE
VARIES
H
F
D
C
2"
PIER PIPE
1
ENGINEERED
FOUNDATION
DIAGONAL BRACING,
AS NEEDED
2" CROSS PIPE
1
IRONRIDGE RAIL
PV MODULE
IRONRIDGE STOPPER SLEEVE
IRONRIDGE UNIVERSAL
FASTENING OBJECT
FOUNDATION DEPTH
PIER EMBEDMENT =
2/3 FNDN DEPTH
2" PIPE
1
CONCRETE
FOUNDATION,
2500PSI MIN
2" PIPE
1
FOUNDATION DEPTH
*ADDITIONAL ENGINEERING REQUIRED
2" PIPE
1
FOUNDATION DEPTH
BY OTHERS,
SPECIFICATIONS
VARY
*ADDITIONAL ENGINEERING REQUIRED
PV MODULE FRAME
IRONRIDGE RAIL
IRONRIDGE STOPPER SLEEVE
IRONRIDGE UNIVERSAL
FASTENING OBJECT
1"
IRONRIDGE STOPPER
SLEEVE
PV MODULE FRAME
IRONRIDGE RAIL
IRONRIDGE UNIVERSAL
FASTENING OBJECT
1"
PV MODULE FRAME
3
8
"
IRONRIDGE UNIVERSAL
FASTENING OBJECT
IRONRIDGE UNIVERSAL
FASTENING OBJECT
PV MODULE FRAME
IRONRIDGE RAIL
2" PIPE
1
IRONRIDGE
2" TOP CAP
XR1000 RAIL
PV MODULE,
BY OTHERS
IRONRIDGE
2" RAIL
CONNECTOR
PIPE FITTINGS DETAIL
2" PIPE
1
IRONRIDGE
2" TOP CAP
XR1000 RAIL
PV MODULE,
BY OTHERS
IRONRIDGE
2" RAIL
CONNECTOR
PIPE FITTINGS DETAIL
IRONRIDGE UNIVERSAL
FASTENING OBJECT
SHEET NAME
JOB NO.
ISSUE DATE
SHEET NO.
SHEET SIZE
24X36
1495 ZEPHYR AVE, HAYWARD, CA 94544
800.227.9523 IRONRIDGE.COM
NOT FOR
CONSTRUCTION
REVISION HISTORY
APPROVAL STATUS
REV DESCRIPTION DATE
2.09 GM
PV SYSTEM
DETAILS
3-UP 2"
XX NOV 2015
IR 1
Scale: 1/2"=1'-0"
3-UP - PV SYSTEM PLAN DETAIL
A
Scale: 3/4"=1'-0"
3-UP - PV SYSTEM SIDE SECTION
B
CLIENT NAME
PROJECT NAME
PROJECT
ADDRESS
SYSTEM KW DC
IRONRIDGE
GROUND MOUNT SYSTEM
Scale: 3/4"=1'-0"
DRILL/POUR FOUNDATION
J
Scale: 3/4"=1'-0"
DRIVEN PIER FOUNDATION
K
Scale: 3/4"=1'-0"
HELICAL PILE FOUNDATION
L
6"=1'-0"
DETAIL, END CLAMP PLAN
G
6"=1'-0"
DETAIL, END CLAMP FRONT
H
6"=1'-0"
DETAIL, MID CLAMP PLAN
E
6"=1'-0"
DETAIL, MID CLAMP FRONT
F
3"=1'-0"
PIPE FITTINGS DETAIL
C
3"=1'-0"
PIPE FITTINGS DETAIL
D
SHEET NOTES
SNOW LOAD, PSF
EXPOSURE CAT
MODULE TYPE
RISK CAT
WIND SPEED, MPH
MODULE W DC
MODULE QTY
-
-
-
-
72-CELL, GENERIC
1. SCHEDULE 40 PIPE OR ALLIED MECHANICAL TUBING (12GA WALL THICKNESS)