2021 IRONRIDGE, INC. VERSION 3.1 FLUSH MOUNT INSTALLATION MANUAL - 14
TILE 
Remove tile and mark rafter. Measure up 6 5/8" from 
bottom of tiles and mark horizontally. Align QBase over 
rafter center and drill two 7/32" pilot holes, back ll with 
roong manufacturers' approved sealant. Place grade-8 
Cap Screw under QBase, lag QBase into rafter location. 
Install Sub-ashing, waterproof at underlayment level 
according to roong manufacturers' instructions and the 
Tile Roong Industry Alliance guidelines. Cut tile with 
diamond blade to allow post to pass through. Place tile 
in position and then install Post. Install 18"x18" ashing, 
pre-bent to follow the contour of the tile as required. Apply 
sealant where Post and Flashing meet and install EPDM 
counter ashing. Attach L-Foot on Stando with hardware. 
Torque to 174 in-lbs (14.5 ft-lbs). Attach rails to L-Foot 
using Bonding Hardware and torque to 250 in-lbs (21-ft-
lbs). 
 ➢ For additional details refer to the full QMPV Installation Manual. 
ADDITIONAL ROOF TYPES
QMPV QBASE METAL, SHAKE AND SLATE
The QMPV QBase can be used to install on multiple 
roong types with dierent installation methods. 
 ➢ For instructions on installing the QBase on Slate refer to the full 
Quick Mount PV Installation Manual.
 ➢ For instructions on installing the QBase on Shake refer to the full 
Quick Mount PV Installation Manual.
 ➢ For instructions on installing the QBase on Metal Shingle refer to 
the full QMPV Installation Manual.
QMPV QBASE UNIVERSAL TILE MOUNT
Locate roof rafters and mark locations on roof, remove 
shakes directly above mount if needed to expose felt 
paper. Level out installation area and location installation 
point, mark. Drill 7/32" pilot hole, 
back ll with roong 
manufacturers' approved sealant. Prepare Hanger Bolt 
with Hex Nut and Sealing washer, insert into QBlock hole 
and drive into rafter until fully seated and the QBlock no 
longer swivels easily. Insert EPDM washer over hanger 
bolt and then install L-Foot in desired orientation and 
torque hardware to 132 in-lbs (11 ft-lbs). Attach rail to 
L-Foot with Bonding Hardware and torque to 250 in-lbs 
(21 ft-lbs).
 ➢ For additional details refer to the full QMPV Installation Manual. 
QMPV CLASSIC SHAKE MOUNT
Torque to 
174 in-lbs