Contour Install instructions

©
2022 IRONRIDGE, INC. VERSION 3.5 FLUSH MOUNT INSTALLATION MANUAL - 8
EXPANSION JOINTS
BOSS
Insert BOSS into rst Rail up to the Alignment Circle, Slide
second Rail over BOSS to the second Alignment Circle,
leaving a 1" gap between the Rails.
There must be a 1" of space between the edge of the Rail
and the edge of the panel to allow proper installation of the
UFO and Stopper Sleeve.
A A
B B
C C
D D
E E
F F
8
8
7
7
6
6
5
5
4
4
3
3
2
2
1
1
No Modules Over Gap
One Bonding Strap Per Break In
Array
A A
B B
C C
D D
E E
F F
8
8
7
7
6
6
5
5
4
4
3
3
2
2
1
1
No Modules Over Gap
No Bonding Strap required for
BOSS
Expansion Joints are required every 100' of continuous rail to allow for thermal expansion and contraction of the system.
Do not install modules over expansion joint.
1" Gap Alignment
Circles