Contour Install instructions
Table Of Contents
©
2022 IRONRIDGE, INC. VERSION 3.5 FLUSH MOUNT INSTALLATION MANUAL - 15
LOW SLOPE ROOFS
Flat Roof Attachment can be used with an L-foot for ush 
mounting modules on low sloped roofs. Mark locations 
for Flat Roof Attachment. Screws should be installed 
symmetrically to each other. If using a membrane ashing, 
remove the silicone washer's protective liner prior to 
attaching the membrane. Attach L-foot with washers and 
3/8” hardware torqued to 250 in-lbs (21 ft-lbs). Seal 
attachment and/or membrane per roong manufacturer’s 
requirements.
 ➢ Type, size, and quantity of roof screws to be specied by 
Structural Engineer. Fastener size not to exceed #15.
 ➢ Membrane ashing available for TPO, PVC, and KEE roofs. 
Ensure membrane ashing is compatible with existing roong 
material.
 ➢ If membrane ashing is not used, only washer on top of L-Foot is 
required.
 ➢ Standalone Flat Roof Attachment Manual available on website. 
250 in-lbs
Flat Roof
Attachment
Hardware
L-Foot
Flat Roof
Attachment
Membrane
Flashing
FLAT ROOF ATTACHMENT
Locate the desired mount placement over a rafter. Using 
the base as a template, mark the two penetration
points. Drill two 7/32" pilot holes, back ll with roong 
manufacturers' approved sealant. Place the grade-8 hex 
bolt in the bottom of the base and screw the Post. Attach 
L-Foot on Stando with hardware. Torque to 174 in-lbs 
(14.5 ft-lbs). Attach rail to L-Foot with Bonding Hardware 
and torque to 250 in-lbs (21 ft-lbs).
The mount can be ashed with available 9", 12" or 
18" aluminum ashings, pitch pocket or curb, or with a 
membrane cone ashing. If using a membrane ashing 
utilize the services of a qualied roofer
 ➢ For additional details refer to the full QM Installation Manual. 
QM QBASE MOUNT
Screws provided by 
others. Shown for 
refrence
Torque to 
174 in-lbs
METAL ROOF
Locate the desired mount placement over a roong seam, 
make sure block is fully seated on metal seam. Torque 
Set Screws to 150 in-lbs(12.5 ft-lbs) using 3/16" Hex 
Drive, alternate driving each bolt till required torque is met.  
Slide Hex Bolt into slot and to desired position. Place rail 
attachment bracket over Hex Bolt and secure with Flange 
Nut, torque Flange Nut to 150 in-lbs(12.5 ft-lbs) using 
1/2" socket.
 ➢ For additional details refer to the full QM Installation Manual. 
 ➢ Certication of Lynx calmp includes bonding to both painted and 
galvalume metal roofs.
QM LYNX 
Slide hardware in to 
desired position 
Torque to 
150 in-lbs










