Contour Install instructions
Table Of Contents
©
2022 IRONRIDGE, INC. VERSION 3.5 FLUSH MOUNT INSTALLATION MANUAL - 15
LOW SLOPE ROOFS
Flat Roof Attachment can be used with an L-foot for ush
mounting modules on low sloped roofs. Mark locations
for Flat Roof Attachment. Screws should be installed
symmetrically to each other. If using a membrane ashing,
remove the silicone washer's protective liner prior to
attaching the membrane. Attach L-foot with washers and
3/8” hardware torqued to 250 in-lbs (21 ft-lbs). Seal
attachment and/or membrane per roong manufacturer’s
requirements.
➢ Type, size, and quantity of roof screws to be specied by
Structural Engineer. Fastener size not to exceed #15.
➢ Membrane ashing available for TPO, PVC, and KEE roofs.
Ensure membrane ashing is compatible with existing roong
material.
➢ If membrane ashing is not used, only washer on top of L-Foot is
required.
➢ Standalone Flat Roof Attachment Manual available on website.
250 in-lbs
Flat Roof
Attachment
Hardware
L-Foot
Flat Roof
Attachment
Membrane
Flashing
FLAT ROOF ATTACHMENT
Locate the desired mount placement over a rafter. Using
the base as a template, mark the two penetration
points. Drill two 7/32" pilot holes, back ll with roong
manufacturers' approved sealant. Place the grade-8 hex
bolt in the bottom of the base and screw the Post. Attach
L-Foot on Stando with hardware. Torque to 174 in-lbs
(14.5 ft-lbs). Attach rail to L-Foot with Bonding Hardware
and torque to 250 in-lbs (21 ft-lbs).
The mount can be ashed with available 9", 12" or
18" aluminum ashings, pitch pocket or curb, or with a
membrane cone ashing. If using a membrane ashing
utilize the services of a qualied roofer
➢ For additional details refer to the full QM Installation Manual.
QM QBASE MOUNT
Screws provided by
others. Shown for
refrence
Torque to
174 in-lbs
METAL ROOF
Locate the desired mount placement over a roong seam,
make sure block is fully seated on metal seam. Torque
Set Screws to 150 in-lbs(12.5 ft-lbs) using 3/16" Hex
Drive, alternate driving each bolt till required torque is met.
Slide Hex Bolt into slot and to desired position. Place rail
attachment bracket over Hex Bolt and secure with Flange
Nut, torque Flange Nut to 150 in-lbs(12.5 ft-lbs) using
1/2" socket.
➢ For additional details refer to the full QM Installation Manual.
➢ Certication of Lynx calmp includes bonding to both painted and
galvalume metal roofs.
QM LYNX
Slide hardware in to
desired position
Torque to
150 in-lbs