Manual

©
2021 IRONRIDGE, INC. VERSION 3.1 FLUSH MOUNT INSTALLATION MANUAL - 2
RATINGS
Product markings are located on the Grounding Lug bolt
head.
MARKINGS
UL 2703 LISTED
Conforms to STD UL 2703 (2015) Standard for Safety First Edition: Mounting Systems, Mounting Devices, Clamping/
Retention Devices, and Ground Lugs for Use with Flat-Plate Photovoltaic Modules and Panels.
Certied to CSA STD LTR AE-001-2012 Photovoltaic Module Racking Systems.
Max Overcurrent Protective Device (OCPD) Rating: 25A
Max Module Size: 25.6 ft²
Max Frameless Module Size for Canadian LTR-AE: 21.5 ft²
Module Orientation: Portrait or Landscape
CAMO Specic Allowable Design Load Rating: 50 PSF downward, 50 PSF upward, 15 PSF lateral
LTR AE Canadian Load Rating: 2400 PA
System Level Allowable Design Load Rating: meets minimum requirements of the standard (10 PSF downward, 5
PSF upward, 5 PSF lateral). Actual system structural capacity is dened by PE stamped certication letters.
CLASS A SYSTEM FIRE RATING PER UL 2703
Any Roof Slope with Module Types 1, 2, 3, 13, 19, 25 & 29.
Any module-to-roof gap is permitted, with no perimeter guarding required. This rating is applicable with any third-party
attachment.
Class A rated PV systems can be installed on Class A, B, and C roofs without a󰀨ecting the roof re rating.
WATER SEAL RATINGS:
UL 441 (FLASHFOOT2, L-MOUNT, FLASHVUE, ALL TILE HOOK, KNOCKOUT TILE, QBOX)
TAS 100(A)-95 (FLASHFOOT2, ALL TILE HOOK, KNOCKOUT TILE, FLASHVUE)
• Tested and evaluated without sealant.
Any roong manufacturer approved sealant is allowed. Ratings applicable for roof slopes between 2:12 and 12:12
STRUCTURAL CERTIFICATION
Designed and Certied for Compliance with the International Building Code & ASCE/SEI-7
FLORIDA PRODUCT APPROVAL #FL29843
Conforms to TAS202, TAS100(A)
Approved for installation both inside and outside High Velocity Hurricane Zones (HVHZ)
Allowable design pressure up to +100/-100 PSF
Additional details and full list of approved components can be found Here.