Manual

©
2021 IRONRIDGE, INC. VERSION 3.1 FLUSH MOUNT INSTALLATION MANUAL - 15
LOW SLOPE ROOFS
Flat Roof Attachment can be used with an L-foot for ush
mounting modules on low sloped roofs. Mark locations
for Flat Roof Attachment. Screws should be installed
symmetrically to each other. If using a membrane ashing,
remove the silicone washer's protective liner prior to
attaching the membrane. Attach L-foot with washers and
3/8” hardware torqued to 250 in-lbs (21 ft-lbs). Seal
attachment and/or membrane per roong manufacturer’s
requirements.
Type, size, and quantity of roof screws to be specied by
Structural Engineer. Fastener size not to exceed #15.
Membrane ashing available for TPO, PVC, and KEE roofs.
Ensure membrane ashing is compatible with existing roong
material.
If membrane ashing is not used, only washer on top of L-Foot is
required.
Standalone Flat Roof Attachment Manual available on website.
250 in-lbs
Flat Roof
Attachment
Hardware
L-Foot
Flat Roof
Attachment
Membrane
Flashing
FLAT ROOF ATTACHMENT
Locate the desired mount placement over a rafter. Using
the base as a template, mark the two penetration
points. Drill two 7/32" pilot holes, back ll with roong
manufacturers' approved sealant. Place the grade-8 hex
bolt in the bottom of the base and screw the Post. Attach
L-Foot on Stando󰀨 with hardware. Torque to 174 in-lbs
(14.5 ft-lbs). Attach rail to L-Foot with Bonding Hardware
and torque to 250 in-lbs (21 ft-lbs).
The mount can be ashed with available 9", 12" or
18" aluminum ashings, pitch pocket or curb, or with a
membrane cone ashing. If using a membrane ashing
utilize the services of a qualied roofer
For additional details refer to the full QMPV Installation Manual.
QMPV QBASE MOUNT
Screws provided by
others. Shown for
refrence
Torque to
174 in-lbs