Installation Manual

ELECTRICAL INSTALLATION
Models | AE-46, E-46, AE-42, E-42, UD-42
ATTENTION:
TURN OFF POWER AT SERVICE ENTRANCE BEFORE
INSTALLING, WIRING, OR SERVICING THIS PRODUCT
ITEMS TO NOTE
Instructions for electrical models ONLY
DO NOT attempt to install your own outlet or
electrical hook-up in non-electrical models
NE-46, NE-42, ANE-46, ANE-42, or IAW-42. This
can cause an electrial hazard and will void the
warranty of your unit.
All electrical work must be done in accordance with
all applicable electrical codes.
SUPPLY LINE 110 Volt/15 AMPS.
STEP ONE: Prepare Electrical Raceway
STEP FOUR: Connect Electrical Wires
STEP TWO: Remove Electrical Knockout
STEP THREE: Prepare Raceway
TURN POWER OFF AT SERVICE ENTRANCE.
Then, begin installation by removing the screws at the top
and bottom of electrical raceway to access the inside.
A black and white pigtail are provided for electrical
hook-up located near bottom of raceway. Connect supply
wires to these pigtails.
DO NOT attempt to connect to any other location inside
the electrical raceway. Doing so will cause the electrical
features to malfunction.
A green ground wire is provided and secured with a star
washer to the back of the electrical channel. Connect
your own ground to that location or attach to the location
opposite the existing ground and add your own star
washer.
Locate and remove the knockout at the top of the raceway
and install a 3/8” Romex connector in its location.
If surface mounting, a vent hole will need be made
through the back side of the cabinet, 24 1/2” down from
top of cabinet, and 2 13/16” from cabinet le side.
Verify that there is ample supply wire (48” is
recommended) available to run from the top of the ironing
center to the location of the provided black and white
pigtails.
Begin to place the ironing center into its location
(supported by cleat if recessed or with the 2 x 4 braces if
surface mounted) while feeding supply wire through the
designated vent hole.
Return to Swivel or Non-Swivel instructions to complete
installation of unit to the wall. When finished, return to
complete final steps here.
INSTALLATION COMPLETE!
ELECTRICAL | PG. 7