AE 42 Specification Packet

RECESSED CLEARANCE - SWIVEL ROTATION
Minimum required space for the ironing board to lower
completely and swivel without hitting an obstacle.
RECESSED
MOUNT
SURFACE
MOUNT
1. Clearance from Wall to
Tip of Board
46 7/8” 50 7/8”
2. Le/Right Clearance for
Swivel
14 5/8”
13 1/8”
14 5/8”
13 1/8”
3. Hinge Side Clearance for
180º Degree Door Swing
16” 16”
Swivel Clearance Requirements
For Further Review
1. Board MUST come down fully in order to
swivel
Because the ironing board needs to clear the sides of
the cabinet before it can swivel, the board needs to be
able to drop down all the way to engage the swivel
mechanism, requiring 46 7/8” in front of the recessed
unit, or 50 7/8” clearance for surface mount units.
2. Adequate space required on both sides of
cabinet for board to swivel
Because the swivel mechanism is positioned under
the middle portion of the ironing board, you will want
to ensure proper clearance on both sides of the unit,
regardless of which direction you will be swiveling the
board. The minimum requirement needed to swivel the
board 90º to the le is 14 5/8” to the right of the cabinet
and 13 1/8” to the le. To ensure the board can swivel
both directions, you will need 14 5/8” on both sides of
the cabinet.
3. Door MUST be able to open 180º
The door needs to open flush against the wall in order for
the swivel to freely turn le or right, requiring 16” on the
hinge side for a flush open. Door can be hinged on either
the le or right side of the ironing center.
Items to Note:
Page 2 of 3 Page 3 of 3
Electrical Requirements for AE-42
Unit requires 115/120v, 15 amp. supply line. Pigtails are
provided in the bottom of wire raceway for hookup to
supply line. Make entrance into knockout provided in top
of raceway through le-hand vent hole.
Installation Types
Recessed
Placed into the wall, between 16” on center studs,
protruding 3 7/8” into the room. It is recommended to
attach a 2” x 4” cleat to studs, level with bottom of the
opening to support cabinet when installing.
Surface Mount
Installed directly onto the wall, with no cutout, centered
and anchored on secure stud. Will protrude 7 3/4” into
room. Optional surface mount kit is available to finish
sides of unit and recommended for complete installation.
Recommended Standing Room Clearance
Be sure to check that you have adequate standing space
(at least 24”) to stand beside the ironing board to iron.
Installation Heights
Use the provided Installation Height Chart on page 1
to determine your desired ironing board height, making
note of the two height positions of the board. The
Desired Ironing Board Height is the first position the
board is automatically placed when first lowering the
board. The Adjusted Position is 4” higher and can be
engaged aer the board has been fully lowered.
Swivel
Swivel feature allows board to turn 90° in either direction,
for a full 180° swivel, with five locking positions.
Door
Ironing center comes standard with a flat maple veneer
door and a variety of additional door options. Door
opens approximately 180°, flush against the wall. Please
be sure to allow 16” to the side of unit for the door to fully
open.
Hinge Side
Unit comes standard with the hinge on the right. A le
side hinge can be requested when placing order.
Unfinished Cabinet
The exterior of the cabinet is unfinished and ready to be
painted or stained to match existing decor.
Questions?
Give us a call at 1-800-536-9495