• Mount receiver in a suitable location, adjacent to the pool lighting transformers.
(Minimum elevation above ground is 500mm)
• Plug receiver into the mains supply
• Plug pool light transformer into outlet marked ‘POOL’
• Plug spa light transformer into outlet marked ‘SPA’
Note: For systems with 2 or more pool lights, use the LV50-12 transformer and
utilise the piggyback feature on the LV50-12 to ensure all transformers are
switched together.
The iRIS lighting system is designed to be used with the Spa Electrics MULTI PLUS model lights. (Please check product
labeling to ensure it is suitable)
For Retro-fit installations, where existing transformers have been hardwired; a suitably qualified electrician must
disconnect the transformers and terminate with a plug top connection. OR the transformers are to be replaced with the
Spa Electrics LV25-12 or LV50-12 models.
Spa Electrics
WWW.SPAELECTRICS.COM.AU
NEED ASSISTANCE? CALL US ON 03 9793 2299 OR VISIT
The iRIS lighting controller has a QUICK SETUP feature to
program the MULTI PLUS lights for iRIS operation.
STEP 1
Ensure the lights have been OFF for a minimum of 30
seconds, then turn the system ON using the iRIS handset.
STEP 2
Press the following static colours in order with a 1 second
pause between each press.
1. WHITE
2. RED
3. GREEN
If performed correctly, the lights will illuminate GREEN.
Confirm correct operation by selecting a different colour
using the iRIS handset.
1. Turn Lights ON
2. Press WHITE
3. Press RED
4. Press GREEN