Operation Manual
IRISPowerscan
TM
– User Guide
115
a single file per batch, document or image.
A formula consists of variable fields and absolute values. The
absolute values are put between double quotation marks. During
the examination of a formula, IRISPowerscan replaces the
variable fields by their absolute and maintains the absolute
values (while leaving out the quotation marks).
E.g. <BATCH_PROCESS_PATH>\"sub_folder"
During the examination, the variable field
BATCH_PROCESS_PATH will be replaced by its value. The
default value is "C:\IRISPowerscan\batches".
The absolute value "sub_folder" will be maintained, but without
quotation marks.
So, the end result will be C:\IRISPowerscan\batches\sub_folder.
To determine a formula, select the fields of your choice from the
Fields list and click Add to add them. Make sure to add a back
slash (\) between two fields.
Note: when you add the back slashes from the Fields, double
quotations marks are added in front and behind them. The
quotations marks are required to obtain a valid formula.
Caution: do not put a back slash in front of the file extension
field, however.