Wireless Digital Flat Panel Detector Mars1417V User Manual Document Version: A1 Document ID: 085-201-02 Release Date: 2019-08-06 Before operating, please read this user manual and pay attention to all safety precautions. Please ensure that this user's manual is properly maintained so that it can be accessed at any time (reserve). Please use it correctly on the basis of full understanding of the content.
To Customer Congratulations on your purchase of iRay Mars1417V (configuration: Mars1417V3) Digital Flat Panel. At iRay, we strive to not only make the world-class products that deliver the best value to our users but also offer the highest quality of service and customer care. Please take time to read user manual to utilize the product effectively. We hope you enjoy the experience with Mars1417V (configuration: Mars1417V3). If you have any questions or suggestions, please feel free to contact us.
Mars1417V Digital Flat Panel Detector User Manual Caring for your environment This symbol indicates that this product is not to be disposed of with your residential or commercial waste Recycling iRay Equipment Please do not dispose of this product with your residential or commercial waste. Improper handling of this type of waste could have a negative impact on health and on environment.
To Customer Symbols and Conventions The following symbols and conventions are used in user manual. This symbol is used to identify conditions under which improper use of the product may cause death or serious personal injury. This notice is used to identify conditions under which improper use of the product may cause minor personal injury. This notice is used to identify conditions under which improper use of the product may cause property damage. This is used to indicate a prohibited operation.
Mars1417V Digital Flat Panel Detector User Manual This symbol is used to identify the manufacture series number which is after, below or adjacent to the symbol. The series number of iRay products is usually made of nineteen digits as shown below: A1A2A3A4 B1B2 C1C2 L M1M2 D1D2 Y1Y2 X1X2X3X4 Numerical Order Year Date Month Production site Version Derived classes Product Code This symbol indicates the name and address of manufacturer.
To Customer Package symbol, fragile. Package symbol, keep away from sunlight. Package symbol, keep dry. This symbol indicates the humidity limits. Keep the product up right Do not roll the transportation package. This symbol indicates stacking limit number. Type-B applied part IPX1 for working surface only iRay Technology Co. Ltd.………………………………………………………………………………………………………………… …………….………..
Mars1417V Digital Flat Panel Detector User Manual Contents SAFETY.................................................................................................................... 11 1. 1.1. Safety precautions......................................................................................................................... 11 1.2. Notes for Using............................................................................................................................... 16 2.
Contents 2.9.9. Use Environment........................................................................................................................31 2.10. IT network.................................................................................................................................... 31 2.10.1. Purpose for IT-network.............................................................................................................. 31 2.10.2. Required characteristics......................
Mars1417V Digital Flat Panel Detector User Manual 4.4. Correction and Calibration Template Generation..................................................................57 4.4.1. Pre-offset Template Generation................................................................................................. 57 4.4.2. Gain Calibration Template Generation..................................................................................... 59 4.4.3. Defect Correction Template Generation......................
Contents 5.3. Radio Frequency Compliance Information..............................................................................87 5.3.1. FCC Compliance........................................................................................................................87 5.4. Battery Safety Standards............................................................................................................. 88 6. TROUBLE SHOOTING.....................................................................
Mars1417V Digital Flat Panel Detector User Manual 1. SAFETY......................................................................................................................11 1.1. Safety precautions......................................................................................................................... 11 1.2. Notes for Using............................................................................................................................... 16 10 .........................
Safety 1. Safety 1.1. Safety precautions Follow these safeguards and properly use the product to prevent injury and damage to it. WARNING Installation and environment of use Do not use or store the product near flammable chemicals such as alcohol, thinner, benzene, etc. If chemicals are spilled or evaporated, it may result in fire or electric shock through contact with electric parts inside the product. Also, some disinfectants are flammable. Be sure to take care when using them.
Mars1417V Digital Flat Panel Detector User Manual Securely plug the power cord into the AC outlet. If contact failure occurs, or if metal objects come into contact with exposed metal prongs of the plug, fire or electric shock may result. Be sure to turn off the power before connecting or disconnecting the cords. Otherwise, you may get an electric shock that could result in death or serious injury. Be sure to hold the plug or connector to disconnect the cord.
Safety Clean the plug of the power cord periodically by unplugging it from the AC outlet and removing dust or dirt from the plug, its periphery and AC outlet with a dry cloth. If the cord is kept plugged in for a long time in a dusty, humid or sooty place, dust around the plug will attract moisture; this could cause insulation failure that may result in a fire. For safety reasons, be sure to turn off the power when performing inspections indicated in this manual.
Mars1417V Digital Flat Panel Detector User Manual Power supply Always connect three-core power cord plug to a grounded AC power outlet. To make it easy to disconnect the plug at any time, avoid putting any obstacles near the outlet. Otherwise, it may not be possible to disconnect the plug in an emergency. Be sure to ground the product to an indoor grounded connector. Also, be sure to connect all the grounds of system to common ground.
Safety Uniform load:150 kg over the whole area of the surface. Local load:100 kg on an area 4 cm diameter. Be sure to use the product on flat surface so it would not bend. Otherwise, the internal image sensor may be damaged. Be sure to securely hold the product while using it in upright positions. Otherwise, the product may fall over, resulting in injury to user or patient, or may flip over, resulting in damage to the inner device. Keep the same load on the product when acquiring image.
Mars1417V Digital Flat Panel Detector User Manual Please charge battery with charger following GB 9706.1 Standards provided by us Do not mix battery with ones not provided by our company Do not charge battery with broken charger. Substitution of battery inside main unit must be carried out by qualified people Do not touch output connector for adaptor Do not remove the battery when the panel is powered on only with the battery. 1.2.
Safety It’s strongly recommended to remove battery from panel if panel is not used more than 5 days. If battery stores for a long time, it should be charged (30% to 50%) every 3 month or charged (50% to 70%) every 6 month. Contact with the patients parts cleaning, disinfection and sterilization After every examination, wipe the patient contact surfaces with nonflammable disinfectants to prevent the risk of infection, such as benzalkonium chloride, benzalkonium bromide.
Mars1417V Digital Flat Panel Detector User Manual 2. GENERAL DESCRIPTION........................................................................................... 19 2.1. Scope................................................................................................................................................. 19 2.2. Model................................................................................................................................................. 19 2.3. Characteristic.....
General Description 2. General Description Mars1417V (configuration: Mars1417V3, hereinafter referred as Mars1417V) is a cassettesize wireless X ray flat panel detector based on amorphous silicon thin-film transistor technologies. It is developed to provide the highest quality of radiographic image, which contains an active matrix of 2304×2800 with 150um pixel pitch. The greatest feature is Mars1417V supports wireless communication between panel and Workstation. Mars1417V’s power supply includes battery.
Mars1417V Digital Flat Panel Detector User Manual 2.3. Characteristic Wireless static flat panel detector used for general radiography. Cassette-size Sync-shot exposure trigger CsI scintillation screen. Easy to change the cable and update firmware. Battery recycling 2.4. Intended use/ essential performance/ application specification 2.4.1.
General Description Intended OPERATOR: All of use, maintenance and operation steps should be carried out by the operator who has accepted the professional training offered by the company's customer service staff. Life-time: Life-time: 7 years without frequency limit 2.6.
Mars1417V Digital Flat Panel Detector User Manual Mars1417V Detector Medical Adapter 1pcs Main Unit 1 pcs DC 24V 2 pcs Battery Battery pack Ethernet Cable 1pcs (Only for service) 3.5 m Gigabit Ethernet Cable 22 1pcs 3m ................................................................................................................................................iRay Technology Co. Ltd.
General Description AC Power Cable DC Power Cable Battery Charger 1 pcs 1 pcs 3.5 m 1pcs 1pcs Gain correction data CD-Rom Defect correction map SDK Manual iRay Technology Co. Ltd.……………………………………………………………………………………….………………………… …………….………..
Mars1417V Digital Flat Panel Detector User Manual 2.8. Components Description 2.8.1. Detector AB CDE F External Signals 24 Input Control Panel Item Name Description A DC Jack 24V DC input B Ethernet Port Gigabit Ethernet port C Detector Indicator Detector indicator of control panel D Power Button Power button of control panel E reserved / F Antenna Antenna ............................................................................................................................
General Description 2.8.2. Battery Item Name Description A Battery Label / B Battery Interface 8 Pin Battery connector C Pilot Pin / D Indicator Installation direction indicator 2.8.3. Battery Charger D A B C E G F Item Name Description A Battery Interface A 8 Pin Battery connector B Battery Interface B 5 Pin Battery connector C Battery Interface C 5 Pin Battery connector D Indicator The indicator definition is as follow iRay Technology Co. Ltd.
Mars1417V Digital Flat Panel Detector User Manual E The limit ball plug / F Hand Pull Position / G AC Jack 220V AC input The battery charger indicator definition: A Item A B C Name Power Indicator Charging Indicator Charge Full Indicator X Indicator Lighting Status All off A indicator on B C Description / / / Operating Status No power input AC Power input Multiple batteries inserted A indicator on B and C alternately blink 2 times A and B indicator on A and C indicator on Batt
General Description 2.9. Product Specification 2.9.1. Detector Item Specification Model Mars1417V-TSI (CsI) Image Sensor a-Si (Amorphous Silicon) TFT Pixel Size 150 μm Active Array 2304 x 2800 Active Area (H x V) 345.6mm x 420mm Gray scales 16bit Spatial Resolution 3.3 Lp/mm Image Acquisition Time (Wireless) Both AP mode and Client mode Preview Acquisition Time: 3 sec. Processed Acquisition Time : 5 sec. Cycle Time Min. 8s Power Consumption Max.
Mars1417V Digital Flat Panel Detector User Manual 2.9.2. Battery Item Specifications Model Battery-KV Rated Capacity Typ. 4180mAh @ Discharge 0.2C Nominal Voltage 10.8V Charge Voltage 12.6±0.05V Discharged End Voltage 9V Charging Method CC-CV Operating Temperature Charge 0℃-+60℃, Discharge-10℃-+60℃ Storage Temperature ≤3 month -20℃-+45℃ ≤6 month -20℃-+35℃ Relative Humidity 5%~95% Dimension (L × W × H) 210 x 115 x 7.5 mm Weight 0.28kg 28 ............................................
General Description 2.9.3. Battery Charger Item Specifications Model Charger-Combo Simultaneous Charging 1 battery packs Full charging time ≤3 hours Rated power supply 90~264V(AC) Dimension (L × W × H) 240 x 184 x 38 mm Weight 0.55 kg 2.9.4. Power supply Mars1417V supports both DC Power and Battery package input. Item Specifications DC Power 24V(DC), 0.75A Battery Package 10.8V(DC),1.6A The product must be used with the approved adaptor whose CB certificate number is SG PSB-MD00191.
Mars1417V Digital Flat Panel Detector User Manual 802.11b: Max. 11Mbps Wireless Data Rate 802.11a/g: Max. 54Mbps 802.11n: Max. 300Mbps (MIMO 2x2) 802.11ac: Max. 867Mbps(MIMO 2x2) 2.9.6. Wireless Communication Item Description Wireless Standard IEEE 802.11a/b/g/n/ac 2.412~2.472GHz: ch1~ch13 Frequency Range 5.18~5.24GHz: ch36~ch48 5.745~5.85GHz: ch149~ch165 802.11b: Max. 11Mbps Data Transmission Rate 802.11a/g: Max. 54Mbps 802.11n: Max. 300Mbps (MIMO 2x2) 802.11ac: Max. 867Mbps(MIMO 2x2) 802.
General Description 2.9.8. Mechanical Outlines 2.9.9. Use Environment Temperature Temperature change Humidity Atmospheric Pressure Operating 5~35℃ <1k/min 10%~90% RH 700~1060hPa Storage -20~55℃ <1k/min 5%~95% RH 700~1060hPa Pressure Change <10kp/min (1kp=1.0197E-5Pa) <10kp/min (1kp=1.0197E-5Pa) The Mars1417V serial detectors shall operate at an altitude specified not more than 3000m, the environment is only for detector. 2.10. IT network 2.10.1.
Mars1417V Digital Flat Panel Detector User Manual 2.10.3. Required configuration The wireless card and the detector must work on the same IP segment such as 192.168.8.XXX They must support IEEE 802.11a/b/g/n/ac. 2.10.4. Technical specifications Item Description Wireless Standard IEEE 802.11a/b/g/n/ac 2.412~2.472GHz: ch1~ch13 Frequency Range 5.18~5.24GHz: ch36~ch48 5.745~5.85GHz: ch149~ch165 802.11b: Max. 11Mbps Data Transmission Rate 802.11a/g: Max. 54Mbps 802.11n: Max. 300Mbps (MIMO 2x2) 802.
General Description The manufacturer of x-ray machine should identify, analyze, evaluate and control these risks; subsequent changes to the IT-network could introduce new risks and require additional analysis 2.10.8. Changes to the IT-network include 1. Changes in the IT-network configuration; 2. Connection of additional items to the IT-network; 3. Disconnecting items from the IT-network; 4. Update of equipment connected to the IT-network; iRay Technology Co. Ltd.……………………………………………………………………………………….
Mars1417V Digital Flat Panel Detector User Manual 3. INSTALLATION.......................................................................................................... 35 3.1. Panel Installation............................................................................................................................ 35 3.1.1. Attach Battery Pack....................................................................................................................35 3.1.2. Attach DC Power.............
Installation 3. Installation 3.1. Panel Installation 3.1.1. Attach Battery Pack Mars1417V can be powered by both battery package and DC power. Once battery package is inserted or DC power is on, Panel would be activated immediately. If none of battery and DC power is on, Mars1417V would power off. Please see below for battery installation. Make sure that the connectors on the battery package are pointed to the cave in battery compartment.
Mars1417V Digital Flat Panel Detector User Manual 3.1.2. Attach DC Power Please see below for DC power installation. Connect one end of DC Power Cable to the Medical Adapter As figure is power interface Ethernet interface Connect another end of DC Power Cable to the DC input of the detector. 3.1.3. Booting Up On the control panel, user can press power button to power on/off.
Installation After booting up, user can check the status LED indicator.
Mars1417V Digital Flat Panel Detector User Manual Green ON Exposure enable Green Blinking Image transmission Orange ON Error Orange Blinking Safety mode 3.1.4. Button function The Button function is shown as table below Action FPD Status N.A. / Power ON Power Note No-Action Short-Hold Hold for 4 seconds. Long-Hold Hold for more than 7 seconds, Release Power Key when the POWER indicator is ON.
Installation Unload Battery from battery charger. Insert battery into battery charger. Note the interface position as figure. Press the battery to the bottom of battery compartment. 3.3. Battery lock and activation To ensure the safety of the battery during transportation or storage, the battery can be set to ship mode, that is, the battery is locked without voltage output. So, it needs to exit ship mode before using the battery for the first time.
Mars1417V Digital Flat Panel Detector User Manual Charger Insert the battery; Press the power button about 4s to shut down the detector; In the shutdown state, press the power button for 3 times to exit ship mode. Power on charger; Insert the battery into the charger for 3~5s to exit ship mode 3.4. Software Installation In the case of iDetector not work, please install Microsoft .NET Framework 4.5 first, then install vcredist_x86_2013(or vcredist_x64_vs2013).
Installation Open local interface network management Open local network configuration open IPV4 setting IP and network mask setting Select “Obtain an IP address automatically” iRay Technology Co. Ltd.……………………………………………………………………………………….………………………… …………….………..
Mars1417V Digital Flat Panel Detector User Manual Open browser and type 192.168.1.1 Log into external wireless AP Wireless setup Configure 2.
Installation Configure LAN IP address IP address: 192.168.8.1 Subnet Mask: 255.255.255.0 External wireless AP reboot Apply above settings and reboot your wireless router. Recover local network IPv4 setting IP setting IP address: 192.168.8.188 Network mask setting Subnet mask: 255.255.255.0 Configuration of detector Either Wired Cable can be used to configure detector in wireless client mode. The wired connection should be used by the service operator only. To start configuration with wired cable.
Mars1417V Digital Flat Panel Detector User Manual Click “Detector” Click ”Wifi” Click ”Read Config” Choose “Client” mode Click “Add” Type SSID and Password Click “Apply” Choose SSID and select(There will be √ occurred)” Click “write config” to save parameters. Turn on wireless router. Make sure there are wired connection between router and work station and IP 192.168.8.188. Click “Read wifi Status” to check wireless transmission status, numericl value occurred means the link is up and available.
Installation 3.5.2. Wireless AP Mode To complete wired connection configuration, user has to finish actions listed below. Configuration of detector Either Wired cable can be used to configure panel wireless AP mode. The wired connection should be used by the service operator only. To start wired cable configuration, users should finish the configuration of external wireless AP, then proceed to the steps below. Connect panel to Workstation with Ethernet Cable like 3.4.
Mars1417V Digital Flat Panel Detector User Manual Change channels setting and frequency Click “Country” and choose a country setting Click ”Channel” and choose a clean frequency and channel Click ”write config” 46 ................................................................................................................................................iRay Technology Co. Ltd.
Installation Do not remove wired cable until FPD status from Busy become Ready Since we have chosen default SSID and password, it would connect to wireless AP immediately after powered on next time. Configuration of external wireless card Open local wireless signal list Select SSID detectors; which belongs to Input password and log into system iRay Technology Co. Ltd.……………………………………………………………………………………….………………………… …………….………..
Mars1417V Digital Flat Panel Detector User Manual Open wireless card configuration open IPV4 setting IP setting IP address: 192.168.8.188 Network mask setting Subnet mask: 255.255.255.0 Open SDK and choose product start connection 48 ................................................................................................................................................iRay Technology Co. Ltd.
Operation 4. OPERATION............................................................................................................... 50 4.1. Main Operation................................................................................................................................ 50 4.2. Connection Build............................................................................................................................ 55 4.3. Panel Configuration................................................
Mars1417V Digital Flat Panel Detector User Manual 4. Operation Mars1417V provides SDK for user to integrate panel into their DR system. Additionally, it also provides an application for demonstration, i.e. iDetector. User can use iDetector to control panel without DR system. 4.1. Main Operation To Acquire X ray image is the main operation of Mars1417V. Most importantly, panel should build synchronization with X ray generator.
Operation 4.1.1.2. Work flow Click “Prep” Panel preparation, Wait until the warning message change from “Exposure Prohibit” to “Exposure Enable” Shoot X ray at any time. However the longer time you wait. The worse image would be. So please shoot once x ray generator is ready. After shooting, Click “Acquire” Wait for image uploaded 4.1.1.3. Timing Setting To set a clear scenario for programming, see diagram below for details 1. Workstation receives “prep” request, send command “Clear” to panel. 2.
Mars1417V Digital Flat Panel Detector User Manual 8. X ray generator finishes x ray shooting. 9. Workstation receives “Acquire” request, send command “Data Acquisition” to panel. 10. Panel receives “Data Acquisition” from workstation, start data acquisition operation. 11. Panel completes image acquisition and begins to send data to workstation. 12. Workstation receives all image data from panel which are after calibration if Hardware calibration is on. 4.1.2. Inner2 Mode 4.1.2.1.
Operation 4.1.2.2. Work Flow Click “Prep” Panel preparation Shoot X ray X ray sensor in panel would trigger panel to start image acquisition. Wait for image uploaded 4.1.2.3. Timing Setting To set a clear scenario for program, see diagram below for details Workstation 1 5 Panel X Ray Generator 3 X ray 4 2 1. Workstation receives “prep” request. 2. X ray generator is ready for X ray shooting and begins to release X ray. 3.
Mars1417V Digital Flat Panel Detector User Manual 4.1.3. Freesync Mode 4.1.3.1. Block Diagram Workstation is a host PC device installed with iDetector and SDK. Chapter 3 has described how to establish connection between panel and Workstation. In FreeSync mode, User doesn’t interact with Workstation. After shooting, images would be shown on screen immediately. 4.1.3.2.
Operation 4.1.3.3. Timing Setting 1. X ray generator is ready for X ray shooting and begins to release X ray. 2. Workstation receives “Exposure Prohibited” from Panel. 3. Panel starts uploading Pre-dark image and Light image to Workstation for preview. If hardware offset is selected, panel would do offset first, and then upload preview image. 4. Panel starts uploading Post-dark image to Workstation.
Mars1417V Digital Flat Panel Detector User Manual 2. The rule of Multi-Share control is based on IP address. The second terminal with different IP address is not allowed to operate panel after the first one connected. If there is no command transmission between panel and Workstation over 5 minutes, panel releases access authority. 4.3.
Operation Calibrate module related setting, such as making correction and calibration template, template in panel could be uploaded to workstation, and template in workstation could also be downloaded to panel. Local File module related setting, such as import Raw or DCM image. 4.4.
Mars1417V Digital Flat Panel Detector User Manual Select “Calibrate” Click “Start Templates” Generate Click “Create Offset” Click “Start create offset template file” It will show ”Offset Map Generating” 58 ................................................................................................................................................iRay Technology Co. Ltd.
Operation After “generating”, it would show “Offset MAP Genetated” 4.4.2. Gain Calibration Template Generation Before Gain template generating, make sure SID1.2m, no copper is required, the GUI of the software maybe different with the below figures. On Gain template generating page, there are five images that need to be got Click “start” button Click “PREP”, exposure and start iRay Technology Co. Ltd.……………………………………………………………………………………….………………………… …………….………..
Mars1417V Digital Flat Panel Detector User Manual After exposure, click “Acquire” to get the light image If the value meet the expected value, click “Accept”, then get the other four images. If the value does not meet the expected value, please do not click the “Accept”, and adjust the exposure dose ,then click the “PREP” to get light image again After getting five images, click “Generate” to generate gain template Notes: 1 please use software post offset correction. 4.4.3.
Operation On the “Defect Calibration” page, start exposure, there are 8 images need to be captured. Click “Start” button Click “PREP”, exposure and start After exposure, click “Acquire” to get the light image iRay Technology Co. Ltd.……………………………………………………………………………………….………………………… …………….………..
Mars1417V Digital Flat Panel Detector User Manual If the value meet the expected value, click “Accept”, then get the other 7 images. If the value does not meet the expected value, please do not click the “Accept”, and adjust the exposure dose ,then click the “PREP” to get light image again After getting 8 images, click “Generate” to generate gain template Note: 1 please use software post offset mode. 2.
Operation Workstation, images would be shown on screen 4.5.2. Panel Image Upload Make sure firewall is closed Panel Image is uploaded as following.