INPUT CHARACTERISTICS Limits Units
Minimum Control Current (see figure 1) 5.0 mA
Maximum Control Current for Off-State Leakage @T
A
=+25°C 0.4 mA
Control Current Range (Caution: current limit input LED, see figure 6) 5.0 to 25 mA
Maximum Reverse Voltage 6.0 V
OUTPUT CHARACTERISTICS Limits Units
Transient Overvoltage Protection 600 V
(DC or AC peak)
Operating Voltage 0-280 V(AC) RMS
0-400 V(DC)
Maximum Load Current @ T
A
= +40°C 1.0 A(DC)
5mA Control (see figure 1 and Note 1) 1.0 A (AC) RMS
Maximum Surge Current
non-repetitive, 1 sec. 5
A(DC)
non-repetitive 20 msec. (see figure 2) 20 A(DC)
Maximum On-State Voltage Drop @T
A
=+25°C 2.5 V
For 1A pulsed load, 5mA Control (see figures 3 and 4)
Maximum Off-State Leakage @T
A
=+25°C, ± 400V (see figure 5) 10 µA
Maximum Turn-On Time @T
A
=+25°C (see figure 8) 7 ms
For 1A, 400 V
DC
load, 5mA Control
Maximum Turn-Off Time @T
A
=+25°C (see figure 8) 1 ms
For 1A, 400 V
DC
load, 5mA Control
Maximum Output Capacitance @ 100V
DC
(see figure 7) 50 pF
GENERAL CHARACTERISTICS
Limits Units
Minimum Dielectric Strength, Input-Output 3750 V
RMS
Minimum Insulation Resistance, Input-Output 10
12
Ω
@T
A
=+25°C, 50%RH, 100V
DC
Maximum Capacitance, Input-Output 1.0 pF
Maximum Pin Soldering Temperature (10 seconds maximum) +260
Ambient Temperature Range: Operating -40 to +85 ° C
Storage -40 to +100
Electrical Specifications (-40°C ≤ T
A
≤ +85°C unless otherwise specified)
Connection Diagram
Notes:
!""Load handling capability to 0.2 power factor requires overvoltage protection.