Datasheet

www.irf.com 3
IRS2112(-1,-2,S)PbF
Symbol Definition Min. Typ.Max.UnitsTest Conditions
t
on
Turn-on propagation delay VS = 0 V
t
off
Turn-off propagation delay
t
sd
Shutdown propagation delay 130 160
t
r
Turn-on rise time
t
f
Turn-off fall time
MT Delay matching, HS & LS Turn-on/off
ns
Dynamic Electrical Characteristics
V
BIAS
(V
CC
, V
BS
, V
DD
) = 15 V, C
L
= 1000 pF, T
A
= 25 °C and V
SS
= COM unless otherwise specified. The dynamic
electrical characteristics are measured using the test circuit shown in Fig. 3.
Symbol Definition Min.Typ. Max.UnitsTest Conditions
V
IH
Logic 1 input voltage 9.5
V
IL
Logic 0 input voltage 6.0
V
OH
High level output voltage, V
BIAS
- V
O
0.05 0.2
V
OL
Low level output voltage, V
O
0.02 0.1
I
LK
Offset supply leakage current 50 V
B
= V
S
= 600 V
I
QBS
Quiescent V
BS
supply current 25 100
I
QCC
Quiescent V
CC
supply current 80 180
I
QDD
Quiescent V
DD
supply current 2.0 30
I
IN+
Logic 1 input bias current 20 40 V
IN
= V
DD
I
IN-
Logic 0 input bias current 1.0 V
IN
= 0 V
V
BSUV+
V
BS
supply undervoltage positive going
7.4 8.5 9.6
threshold
V
BSUV-
V
BS
supply undervoltage negative going
7.0 8.1 9.2
threshold
V
CCUV+
V
CC
supply undervoltage positive going
7.6 8.6 9.6
threshold
V
CCUV-
V
CC
supply undervoltage negative going
7.2 8.2 9.2
threshold
I
O+
Output high short circuit pulsed current 200 290
V
O
= 0 V, V
IN
= V
DD
PW 10 µs
I
O-
Output low short circuit pulsed current 420 600
V
O
= 15 V, V
IN
= 0 V
PW 10 µs
Static Electrical Characteristics
V
BIAS
(V
CC
, V
BS
, V
DD
) = 15 V, T
A
= 25 °C and V
SS
= COM unless otherwise specified. The V
IN
, V
TH
, and I
IN
parameters
are referenced to V
SS
and are applicable to all three logic input leads: HIN, LIN, and SD. The V
O
and I
O
parameters are
referenced to COM and are applicable to the respective output leads: HO or LO.
µA
V
mA
V
V
IN
= 0 V or V
DD
I
O
= 2 mA
V
S
= 600 V
PDF created with pdfFactory trial version www.pdffactory.com
135 180
130 160
75 130
35 65
30