Datasheet
3
IR2104
(
S
) & (PbF)
www.irf.com
Symbol Definition Min. Typ. Max. Units Test Conditions
V
IH
Logic “1” (HO) & Logic “0” (LO) input voltage 3 — — V
CC
= 10V to 20V
V
IL
Logic “0” (HO) & Logic “1” (LO) input voltage — — 0.8 V
CC
= 10V to 20V
V
SD,TH+
SD input positive going threshold 3 — — V
CC
= 10V to 20V
V
SD,TH-
SD input negative going threshold — — 0.8 V
CC
= 10V to 20V
V
OH
High level output voltage, V
BIAS
- V
O
— — 100 I
O
= 0A
V
OL
Low level output voltage, V
O
— — 100 I
O
= 0A
I
LK
Offset supply leakage current — — 50 V
B
= V
S
= 600V
I
QBS
Quiescent V
BS
supply current — 30 55 V
IN
= 0V or 5V
I
QCC
Quiescent V
CC
supply current — 150 270 V
IN
= 0V or 5V
I
IN+
Logic “1” input bias current — 3 10 V
IN
= 5V
I
IN-
Logic “0” input bias current — — 1 V
IN
= 0V
V
CCUV+
V
CC
supply undervoltage positive going 8 8.9 9.8
threshold
V
CCUV-
V
CC
supply undervoltage negative going 7.4 8.2 9
threshold
I
O+
Output high short circuit pulsed current 130 210 — V
O
= 0V
PW ≤ 10 µs
I
O-
Output low short circuit pulsed current 270 360 — V
O
= 15V
PW ≤ 10 µs
Symbol Definition Min. Typ. Max. Units Test Conditions
t
on
Turn-on propagation delay — 680 820 V
S
= 0V
t
off
Turn-off propagation delay — 150 220 V
S
= 600V
t
sd
Shutdown propagation delay — 160 220
t
r
Turn-on rise time — 100 170
t
f
Turn-off fall time — 50 90
DT Deadtime, LS turn-off to HS turn-on & 400 520 650
HS turn-on to LS turn-off
Static Electrical Characteristics
V
BIAS
(V
CC
, V
BS
) = 15V and T
A
= 25°C unless otherwise specified. The V
IN
, V
TH
and I
IN
parameters are referenced to
COM. The V
O
and I
O
parameters are referenced to COM and are applicable to the respective output leads: HO or LO.
Dynamic Electrical Characteristics
V
BIAS
(V
CC
, V
BS
) = 15V, C
L
= 1000 pF and T
A
= 25°C unless otherwise specified.
V
mV
V
mA
MT Delay matching, HS & LS turn-on/off — — 60
ns
µA